{"product_id":"honeywell-xnx-utse-fhiv1-methane-gas-detector-transmitter","title":"Honeywell XNX-UTSE-FHIV1 Methane Gas Detector Transmitter","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell XNX-UTSE-FHIV1 Universal Transmitter Data Sheet\u003c\/strong\u003e\u003c\/h2\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eHoneywell XNX-UTSE-FHIV1\u003c\/strong\u003e universal transmitter delivers high performance methane monitoring across hazardous processing areas. Plant engineers install this heavy duty gas detector to protect critical infrastructure against explosive gas buildup. Technicians rely on the \u003cstrong\u003eHoneywell XNX-UTSE-FHIV1\u003c\/strong\u003e transmitter to ensure continuous safety and fast network communication.\u003c\/p\u003e\n\n\u003cp\u003eDownload the official technical manual to view complete wiring diagrams and installation steps: \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/XNX_Universal_Transmitter.pdf?v=1787797330\" target=\"_blank\"\u003eDownload Honeywell XNX Universal Transmitter Manual\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eProduct Executive Summary\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Name:\u003c\/strong\u003e Honeywell Process Solutions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Series:\u003c\/strong\u003e XNX Universal Transmitter Series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecific Model:\u003c\/strong\u003e \u003cstrong\u003eXNX-UTSE-FHIV1\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary Application:\u003c\/strong\u003e Continuous combustible methane gas monitoring in explosive industrial environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCore Feature:\u003c\/strong\u003e Heavy stainless steel enclosure with Foundation Fieldbus and local HART communication support.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications \u0026amp; Performance Parameters\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand Name:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Identification:\u003c\/strong\u003e \u003cstrong\u003eXNX-UTSE-FHIV1\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Target:\u003c\/strong\u003e \u003cspan style=\"color: #d9534f;\"\u003e0 to 100% LEL (0 to 5% Vol.) Methane (CH4) Gas\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time Speed:\u003c\/strong\u003e T90 optical response occurs in less than 15 seconds under standard testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Sensitivity:\u003c\/strong\u003e High optical stability detects minimal methane concentrations without signal drift.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Linearity:\u003c\/strong\u003e Linear digital conversion ensures high accuracy across the complete active range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Resolution:\u003c\/strong\u003e \u003cspan style=\"color: #28a745;\"\u003e1% LEL digital increment steps\u003c\/span\u003e ensure precise control room monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature Limit:\u003c\/strong\u003e Thermal endurance spans from -40 degrees Celsius up to +65 degrees Celsius.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Tolerance:\u003c\/strong\u003e Rugged housing meets strict NEMA 4X and IP66 ingress protection ratings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise Immunity:\u003c\/strong\u003e Internal electronic shielding protects circuit elements against strong electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain Enclosure Body:\u003c\/strong\u003e \u003cspan style=\"color: #007bff;\"\u003e316 Grade Stainless Steel\u003c\/span\u003e prevents corrosion in harsh chemical locations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConduit Entry Connection:\u003c\/strong\u003e Dual 3\/4 inch NPT threaded entry ports accept explosion-proof wiring glands.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Certifications:\u003c\/strong\u003e Official UL and CSA approvals suit Class I Division 1 hazardous areas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePersonality Module:\u003c\/strong\u003e Integrated electrochemical interface includes intrinsic safety barrier board assemblies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFieldbus Bus Card:\u003c\/strong\u003e Built-in Foundation Fieldbus module connects transmitter directly into digital networks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocal Interface Access:\u003c\/strong\u003e Dedicated local HART connection point allows fast technician field servicing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Equipment Mass:\u003c\/strong\u003e Heavy duty housing assembly weighs exactly 6.8 kilograms (15 pounds) total.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Voltage Range:\u003c\/strong\u003e Internal electronics operate on standard 18 to 32 VDC power supply inputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Usage Requirement:\u003c\/strong\u003e Low energy consumption draws less than 6.5 watts during normal operations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eKey Selling Points\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Digital Communications:\u003c\/strong\u003e Foundation Fieldbus links main control systems while local HART enables quick handheld diagnostic testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtreme Marine Durability:\u003c\/strong\u003e Solid 316 stainless steel body resists harsh saltwater spray on offshore platforms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntrinsically Safe Design:\u003c\/strong\u003e Built-in safety barrier allows technicians to service optical sensors without total power shutdown.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInfrared Methane Precision:\u003c\/strong\u003e Advanced optical sensor head delivers fast infrared detection for dangerous methane gas leaks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Modular Architecture:\u003c\/strong\u003e Common internal electronic chassis reduces spare inventory costs across various plant assets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eModel Code Tree Structure\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eXNX\u003c\/strong\u003e → Universal Transmitter Platform\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eU\u003c\/strong\u003e → UL and CSA Safety Approved\n      \u003cul\u003e\n        \u003cli\u003e\n\u003cstrong\u003eT\u003c\/strong\u003e → 3\/4 inch NPT Threaded Conduit Entry\n          \u003cul\u003e\n            \u003cli\u003e\n\u003cstrong\u003eS\u003c\/strong\u003e → 316 Grade Stainless Steel Enclosure\n              \u003cul\u003e\n                \u003cli\u003e\n\u003cstrong\u003eE\u003c\/strong\u003e → Electrochemical IS Barrier Interface\n                  \u003cul\u003e\n                    \u003cli\u003e\n\u003cstrong\u003eF\u003c\/strong\u003e → Foundation Fieldbus Communication Card\n                      \u003cul\u003e\n                        \u003cli\u003e\n\u003cstrong\u003eH\u003c\/strong\u003e → Local HART Test Port Included\n                          \u003cul\u003e\n                            \u003cli\u003e\n\u003cstrong\u003eIV1\u003c\/strong\u003e → Infrared Methane Sensor (0-100% LEL)\u003c\/li\u003e\n                          \u003c\/ul\u003e\n                        \u003c\/li\u003e\n                      \u003c\/ul\u003e\n                    \u003c\/li\u003e\n                  \u003c\/ul\u003e\n                \u003c\/li\u003e\n              \u003c\/ul\u003e\n            \u003c\/li\u003e\n          \u003c\/ul\u003e\n        \u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eModel Comparison \u0026amp; Technical Recommendations\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eXNX-UTSE-FHIV1 Platform:\u003c\/strong\u003e Uses infrared optical sensors tuned specifically for methane gas concentration measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlternative Selection Option:\u003c\/strong\u003e Review specifications for the \u003ca href=\"https:\/\/www.ubestplc.com\/products\/honeywell-xnx-utse-fhif1-universal-transmitter-gas-detector\" target=\"_blank\"\u003eXNX-UTSE-FHIF1\u003c\/a\u003e transmitter model when site target gases require propane detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngineering Advice:\u003c\/strong\u003e Select \u003cstrong\u003eXNX-UTSE-FHIV1\u003c\/strong\u003e for natural gas compression stations requiring direct methane digital telemetry over Fieldbus loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware Similarities:\u003c\/strong\u003e Both transmitters share identical 316 stainless steel housing, local HART access, and Foundation Fieldbus protocols.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eField Installation \u0026amp; Wiring Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Mounting:\u003c\/strong\u003e Secure the heavy stainless housing firmly onto rigid metal mounting frames or walls.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConduit Sealing:\u003c\/strong\u003e Apply approved thread sealant onto 3\/4 inch NPT stainless conduit connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring Steps:\u003c\/strong\u003e Route digital signal wires inside housing and connect conductors onto Foundation Fieldbus terminal blocks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Grounding:\u003c\/strong\u003e Connect heavy copper grounding wire onto external enclosure earth terminals to prevent noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Head Assembly:\u003c\/strong\u003e Thread infrared methane sensor cartridge into lower housing port and hand tighten securely.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eDelivery Packaging \u0026amp; Express Logistics\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Shipping List:\u003c\/strong\u003e Sealed transmitter enclosure unit with Foundation Fieldbus and HART communication circuit boards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal Hardware Items:\u003c\/strong\u003e Pre-installed intrinsic safety barrier card and electrochemical personality board assembly inside housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtective Packaging:\u003c\/strong\u003e Thick custom foam inserts cushion heavy transmitter during international air transit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpress Courier Options:\u003c\/strong\u003e We send fast international shipments using trusted express couriers FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial Warranty Coverage:\u003c\/strong\u003e Factory fresh units include full 12 month warranty coverage against manufacturing defects.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat main gas type does this model detect?\u003c\/strong\u003e This transmitter measures methane gas concentrations from 0 to 100% LEL using infrared sensors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow do engineers access local HART communications?\u003c\/strong\u003e Technicians attach HART handheld calibrators directly to internal test terminals under front enclosure covers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this unit support Foundation Fieldbus protocol loops?\u003c\/strong\u003e Factory installed Foundation Fieldbus cards allow direct integration into smart digital fieldbus control networks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs this heavy housing suitable for corrosive environments?\u003c\/strong\u003e The 316 grade stainless steel construction provides superior protection against aggressive offshore marine atmospheres.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat input power voltage does the electronics require?\u003c\/strong\u003e Internal power supply circuits operate smoothly on standard 18 to 32 VDC direct current inputs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003e© 2026 Ubest Automation Limited. \u003ca href=\"https:\/\/www.ubestplc.com\/\" target=\"_blank\"\u003ehttps:\/\/www.ubestplc.com\/\u003c\/a\u003e All rights reserved.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eContact: Email \u003ca href=\"mailto:sales@ubestplc.com\"\u003esales@ubestplc.com\u003c\/a\u003e Phone \u003ca href=\"https:\/\/wa.me\/8618030005825\" target=\"_blank\"\u003e+86 180 3000 5825\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52770524561690,"sku":"XNX-UTSE-FHIV1","price":197.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/XNX-AMSE-NHNNN_5_04ac51c2-b4c6-4d16-a45d-8435ef67c760.jpg?v=1788142863","url":"https:\/\/www.ubestplc.com\/products\/honeywell-xnx-utse-fhiv1-methane-gas-detector-transmitter","provider":"Ubest Automation Limited","version":"1.0","type":"link"}