{"product_id":"honeywell-xnx-utse-fniv1-transmitter-detector-request-price","title":"Honeywell XNX-UTSE-FNIV1 Transmitter Detector - Request Price","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell XNX-UTSE-FNIV1\u003c\/strong\u003e universal transmitter delivers high-performance industrial gas monitoring across dynamic hazardous operations. This rugged gas detector integrates electrochemical personality hardware with infrared methane sensing to ensure continuous plant protection. Engineers deploy the \u003cstrong\u003eXNX-UTSE-FNIV1\u003c\/strong\u003e to establish reliable hazardous area monitoring and fast system communications.\u003c\/p\u003e\n\u003cp\u003eDownload the official technical manual to review installation diagrams and detailed field wiring diagrams: \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/XNX_Universal_Transmitter.pdf?v=1787797330\" target=\"_blank\"\u003eDownload Honeywell XNX Universal Transmitter Manual\u003c\/a\u003e.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eExecutive Technical Summary\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong\u003eXNX-UTSE-FNIV1\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Class:\u003c\/strong\u003e Universal Gas Transmitter Platform\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCore Purpose:\u003c\/strong\u003e Continuous combustible methane detection in heavy industrial processing locations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKey Advantage:\u003c\/strong\u003e Stainless steel assembly provides high corrosion protection in extreme marine conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Name:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Designation:\u003c\/strong\u003e \u003cstrong\u003eXNX-UTSE-FNIV1\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e \u003cspan style=\"color: #d9534f;\"\u003e0 to 100% LEL (0 to 5% Vol.) Methane\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e T90 response occurs in less than 15 seconds during standard testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Sensitivity:\u003c\/strong\u003e High optical precision detects minimal gas concentrations without baseline drifting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Linearity:\u003c\/strong\u003e Linear signal output maintains precision across the complete active measuring range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Resolution:\u003c\/strong\u003e \u003cspan style=\"color: #28a745;\"\u003e1% LEL digital increment step\u003c\/span\u003e for accurate control room monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e Operating performance covers -40 degrees Celsius to +65 degrees Celsius continuously.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e Heavy enclosure achieves NEMA 4X and IP66 ingress protection ratings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Immunity:\u003c\/strong\u003e Shielded electronics protect internal circuitry against high electromagnetic fields.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing Material:\u003c\/strong\u003e \u003cspan style=\"color: #007bff;\"\u003e316 Stainless Steel\u003c\/span\u003e construction prevents coastal atmospheric corrosion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConduit Entry Size:\u003c\/strong\u003e Dual 3\/4 inch NPT threaded entry ports support industrial wiring glands.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Approvals:\u003c\/strong\u003e Certified under UL and CSA standards for hazardous Class I divisions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePersonality Type:\u003c\/strong\u003e Electrochemical cartridge interface with integral intrinsic safety barrier protection assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFieldbus Interface:\u003c\/strong\u003e Integrated Foundation Fieldbus digital communication card enables direct network architecture connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocal Interface:\u003c\/strong\u003e Configured without local HART test port connection points inside main housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Mass:\u003c\/strong\u003e Enclosure weight measures approximately 6.8 kilograms (15 pounds) total.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eModel Code Structural Breakdown\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Platform Code:\u003c\/strong\u003e XNX → Universal Gas Transmitter Enclosure\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals Subcode:\u003c\/strong\u003e U → UL and CSA Safety Certified\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThreading Subcode:\u003c\/strong\u003e T → 3\/4 inch NPT Entry Size\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing Subcode:\u003c\/strong\u003e S → 316 Grade Stainless Steel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterface Subcode:\u003c\/strong\u003e E → Electrochemical Interface with IS Barrier\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol Subcode:\u003c\/strong\u003e F → Foundation Fieldbus Communication Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHART Option Subcode:\u003c\/strong\u003e N → No Local HART Interface Port\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Subcode:\u003c\/strong\u003e IV1 → Infrared Methane Sensor Cartridge\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eModel Comparison \u0026amp; Engineering Selection\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eXNX-UTSE-FNIV1 Target Application:\u003c\/strong\u003e Optimized for primary methane gas measuring applications using \u003cstrong\u003eIV1\u003c\/strong\u003e designated optical sensor head.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlternative Selection:\u003c\/strong\u003e Engineers specify the \u003ca href=\"https:\/\/www.ubestplc.com\/products\/honeywell-xnx-utse-fnif1-universal-transmitter-gas-detector\" target=\"_blank\"\u003eXNX-UTSE-FNIF1\u003c\/a\u003e transmitter when plant requirements specify alternative infrared hydrocarbon sensor head configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelection Guidance:\u003c\/strong\u003e Select the \u003cstrong\u003eXNX-UTSE-FNIV1\u003c\/strong\u003e when your DCS network demands direct methane concentration measurement over Foundation Fieldbus loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterchangeability Notice:\u003c\/strong\u003e Both field transmitters share identical 316 stainless steel enclosures and internal electrochemical interface barrier setups.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eField Installation Guidelines\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Mounting:\u003c\/strong\u003e Secure the heavy stainless housing onto structural frames using rigid mounting brackets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConduit Connection:\u003c\/strong\u003e Apply approved thread sealant onto the 3\/4 inch NPT stainless steel threads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Preparation:\u003c\/strong\u003e Connect field signal cables directly to Foundation Fieldbus terminal blocks inside housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Procedure:\u003c\/strong\u003e Fasten dedicated grounding conductors to external earth terminals to eliminate noise interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Integration:\u003c\/strong\u003e Insert the optical methane sensor cartridge carefully into the designated lower housing socket.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePackaging \u0026amp; Shipping Logistics\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain Enclosure Unit:\u003c\/strong\u003e One factory sealed transmitter assembly containing internal fieldbus module hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware Package:\u003c\/strong\u003e Includes internal intrinsic safety barrier hardware and specialized electrochemical personality adapter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtective Packaging:\u003c\/strong\u003e Items sit inside shock-absorbing foam inserts within a reinforced shipping box.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlobal Express Partners:\u003c\/strong\u003e We ship orders internationally through trusted courier partners FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat primary gas does this model target?\u003c\/strong\u003e The transmitter monitors methane gas concentrations from 0 to 100% Lower Explosive Limit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhich communication protocol comes factory installed?\u003c\/strong\u003e Honeywell builds this unit with an integrated Foundation Fieldbus digital communication interface board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan technicians connect HART handheld calibrators locally?\u003c\/strong\u003e This specific model variant omits local HART connection points on its exterior housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the housing suitable for offshore marine platforms?\u003c\/strong\u003e The 316 stainless steel construction delivers superior protection against harsh saltwater environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e© 2026 Ubest Automation Limited. \u003ca href=\"https:\/\/www.ubestplc.com\/\" target=\"_blank\"\u003ehttps:\/\/www.ubestplc.com\/\u003c\/a\u003e All rights reserved.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eContact: Email \u003ca href=\"mailto:sales@ubestplc.com\"\u003esales@ubestplc.com\u003c\/a\u003e Phone \u003ca href=\"https:\/\/wa.me\/8618030005825\" target=\"_blank\"\u003e+86 180 3000 5825\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52770501984538,"sku":"XNX-UTSE-FNIV1","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/XNX-AMSE-NHNNN_3_c7ef0a1b-3ebd-4749-b5c3-f0cd77c243ed.jpg?v=1788140514","url":"https:\/\/www.ubestplc.com\/products\/honeywell-xnx-utse-fniv1-transmitter-detector-request-price","provider":"Ubest Automation Limited","version":"1.0","type":"link"}