Honeywell XNX-UTSV-NNIC1 Gas Detector | Buy Gas Transmitter - Inquiry

In stock
Manufacturer:
Honeywell
Product No.:
XNX-UTSV-NNIC1
Condition:
In Stock
Product Type:
Universal Gas Transmitter
Product Origin:
USA
Weight:
6500g
Shipping port:
Xiamen
Warranty:
12 months

UBEST – Trusted Global Automation Parts Supplier

We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.

About Us | Contact

Honeywell XNX-UTSV-NNIC1 Universal Gas Transmitter Product Overview

Engineers deploy the XNX-UTSV-NNIC1 universal gas transmitter to monitor hazardous gas levels in demanding industrial facilities. Honeywell designs this advanced device to deliver reliable carbon dioxide detection across diverse plant environments. Plant operators trust its rugged construction and precise sensor technology to protect personnel and equipment.

  • Manufacturers build this unit for heavy-duty industrial applications requiring robust safety infrastructure.
  • Facility teams utilize the mV interface to connect specialized infrared carbon dioxide sensors seamlessly.
  • Engineers select this transmitter for continuous gas monitoring in offshore platforms and chemical plants.

Technical Specifications and Performance Metrics

Technical professionals evaluate the exact parameters of the XNX-UTSV-NNIC1 before installing safety systems. Honeywell engineers integrate high-grade components to ensure stable operation under extreme environmental conditions. The device specifications highlight its exceptional performance and durability.

  • Brand: Honeywell
  • Model: XNX-UTSV-NNIC1
  • Product Type: XNX Universal Transmitter
  • Sensor Type: IR Carbon Dioxide Sensor
  • Measurement Range: 0 to 5% Vol
  • Output Signal: HART over 4-20mA output
  • Linearity and Resolution: High-precision digital processing ensures accurate gas concentration readings.
  • Temperature Range: Operating temperature spans from minus 40 degrees Celsius to plus 65 degrees Celsius.
  • Environmental Tolerance: Operating humidity ranges from zero to 99 percent non-condensing relative humidity.
  • Pressure Limits: Operating pressure accommodates normal industrial variations from 90 to 110 kilopascals.
  • Enclosure Material: 316 Stainless Steel with painted protective finish for corrosion resistance.
  • Dimensions: Physical dimensions measure 16 centimeters by 19.7 centimeters by 11.4 centimeters.
  • Weight: The complete unit weighs approximately 5 kilograms.

Installation Guide and Mechanical Mounting

Installers follow strict guidelines to mount the transmitter securely within hazardous plant zones. Proper mechanical positioning ensures optimal gas sampling and reliable sensor response during daily operations. Technicians utilize versatile hardware options to complete the installation efficiently.

  • Mounting Method: Surface mount via integral mounting lugs on rigid industrial walls.
  • Optional Hardware: Optional pipe mounting kit suits pipes measuring 100 millimeters to 150 millimeters.
  • Ceiling Option: Optional ceiling mounting bracket accommodates specialized overhead positioning requirements.
  • Conduit Entries: Four separate three-quarter-inch NPT entries simplify electrical cable routing.

Standard Package Contents and Shipping Logistics

Logistics teams prepare complete factory shipments containing all necessary hardware components for immediate site deployment. Reliable global courier partners ensure fast and secure delivery to international project destinations. Project managers receive fully inspected equipment ready for immediate technical commissioning.

  • Package Items: Honeywell XNX Universal Transmitter base unit.
  • Sensor Module: MPD infrared carbon dioxide sensor calibrated for 0 to 5 percent volume.
  • Hardware Included: Integrated mounting lugs and standard factory documentation.
  • Courier Partners: Fast global shipping utilizes Fedex, UPS, and DHL delivery services.

Frequently Asked Questions

Technical support engineers answer common operational questions regarding transmitter configuration and maintenance procedures. Plant operators review these technical inquiries to optimize gas detection performance and troubleshooting efficiency. Clear guidelines help technical staff maintain system reliability over years of service.

  • Question: What gases does this specific transmitter model detect? Answer: The unit detects carbon dioxide within a zero to five percent volume range using an infrared sensor.
  • Question: How do technicians configure the output signal? Answer: Technicians configure the standard HART communication protocol overlaid on a four to 20 milliamp output loop.
  • Question: What storage conditions protect the sensor during warehouse holding? Answer: Store the equipment between minus 40 degrees Celsius and 75 degrees Celsius in non-condensing humidity.

Model Selection Comparison and Technical Advice

Engineering teams frequently compare similar transmitter variants to select the optimal configuration for specific site requirements. Reviewing related product options ensures complete compatibility with existing plant control networks and safety monitoring architectures. Technical advisors recommend evaluating gas types before finalizing procurement orders.

  • Alternative Model: Compare with the Honeywell XNX-AMAV-NHIC1 CO2 Gas Detector for alternative certification requirements.
  • Selection Advice: Verify operating voltage, communication protocols, and hazardous area classifications prior to purchase.
  • Technical Support: Contact engineering sales to confirm sensor compatibility for specialized industrial gas applications.

Product Manual and Technical Documentation

Engineering personnel download official technical manuals to review detailed wiring diagrams and configuration instructions. Accessing manufacturer documentation ensures compliance with local safety standards and correct operational setup. Plant technicians rely on these comprehensive guides during routine maintenance cycles.

  • Manual Download: Access the official XNX Universal Transmitter PDF Manual for complete wiring guides.
  • Documentation Content: Manual includes calibration steps, troubleshooting tables, and safety certification details.

© 2026 Ubest Automation Limited. https://www.ubestplc.com/ All rights reserved.