{"product_id":"honeywell-xnx-utsv-nnic1-gas-detector-buy-gas-transmitter-inquiry","title":"Honeywell XNX-UTSV-NNIC1 Gas Detector | Buy Gas Transmitter - Inquiry","description":"\u003cdiv\u003e\n  \u003ch2\u003e\u003cstrong\u003eHoneywell XNX-UTSV-NNIC1 Universal Gas Transmitter Product Overview\u003c\/strong\u003e\u003c\/h2\u003e\n  \u003cp\u003eEngineers deploy the \u003cstrong\u003eXNX-UTSV-NNIC1\u003c\/strong\u003e universal gas transmitter to monitor hazardous gas levels in demanding industrial facilities. Honeywell designs this advanced device to deliver reliable carbon dioxide detection across diverse plant environments. Plant operators trust its rugged construction and precise sensor technology to protect personnel and equipment.\u003c\/p\u003e\n  \u003cul\u003e\n    \u003cli\u003eManufacturers build this unit for heavy-duty industrial applications requiring robust safety infrastructure.\u003c\/li\u003e\n    \u003cli\u003eFacility teams utilize the mV interface to connect specialized infrared carbon dioxide sensors seamlessly.\u003c\/li\u003e\n    \u003cli\u003eEngineers select this transmitter for continuous gas monitoring in offshore platforms and chemical plants.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch2\u003e\u003cstrong\u003eTechnical Specifications and Performance Metrics\u003c\/strong\u003e\u003c\/h2\u003e\n  \u003cp\u003eTechnical professionals evaluate the exact parameters of the \u003cstrong\u003eXNX-UTSV-NNIC1\u003c\/strong\u003e before installing safety systems. Honeywell engineers integrate high-grade components to ensure stable operation under extreme environmental conditions. The device specifications highlight its exceptional performance and durability.\u003c\/p\u003e\n  \u003cul\u003e\n    \u003cli\u003eBrand: Honeywell\u003c\/li\u003e\n    \u003cli\u003eModel: \u003cstrong\u003eXNX-UTSV-NNIC1\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003cli\u003eProduct Type: XNX Universal Transmitter\u003c\/li\u003e\n    \u003cli\u003eSensor Type: IR Carbon Dioxide Sensor\u003c\/li\u003e\n    \u003cli\u003eMeasurement Range: 0 to 5% Vol\u003c\/li\u003e\n    \u003cli\u003eOutput Signal: HART over 4-20mA output\u003c\/li\u003e\n    \u003cli\u003eLinearity and Resolution: High-precision digital processing ensures accurate gas concentration readings.\u003c\/li\u003e\n    \u003cli\u003eTemperature Range: Operating temperature spans from minus 40 degrees Celsius to plus 65 degrees Celsius.\u003c\/li\u003e\n    \u003cli\u003eEnvironmental Tolerance: Operating humidity ranges from zero to 99 percent non-condensing relative humidity.\u003c\/li\u003e\n    \u003cli\u003ePressure Limits: Operating pressure accommodates normal industrial variations from 90 to 110 kilopascals.\u003c\/li\u003e\n    \u003cli\u003eEnclosure Material: 316 Stainless Steel with painted protective finish for corrosion resistance.\u003c\/li\u003e\n    \u003cli\u003eDimensions: Physical dimensions measure 16 centimeters by 19.7 centimeters by 11.4 centimeters.\u003c\/li\u003e\n    \u003cli\u003eWeight: The complete unit weighs approximately 5 kilograms.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch2\u003e\u003cstrong\u003eInstallation Guide and Mechanical Mounting\u003c\/strong\u003e\u003c\/h2\u003e\n  \u003cp\u003eInstallers follow strict guidelines to mount the transmitter securely within hazardous plant zones. Proper mechanical positioning ensures optimal gas sampling and reliable sensor response during daily operations. Technicians utilize versatile hardware options to complete the installation efficiently.\u003c\/p\u003e\n  \u003cul\u003e\n    \u003cli\u003eMounting Method: Surface mount via integral mounting lugs on rigid industrial walls.\u003c\/li\u003e\n    \u003cli\u003eOptional Hardware: Optional pipe mounting kit suits pipes measuring 100 millimeters to 150 millimeters.\u003c\/li\u003e\n    \u003cli\u003eCeiling Option: Optional ceiling mounting bracket accommodates specialized overhead positioning requirements.\u003c\/li\u003e\n    \u003cli\u003eConduit Entries: Four separate three-quarter-inch NPT entries simplify electrical cable routing.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch2\u003e\u003cstrong\u003eStandard Package Contents and Shipping Logistics\u003c\/strong\u003e\u003c\/h2\u003e\n  \u003cp\u003eLogistics teams prepare complete factory shipments containing all necessary hardware components for immediate site deployment. Reliable global courier partners ensure fast and secure delivery to international project destinations. Project managers receive fully inspected equipment ready for immediate technical commissioning.\u003c\/p\u003e\n  \u003cul\u003e\n    \u003cli\u003ePackage Items: Honeywell XNX Universal Transmitter base unit.\u003c\/li\u003e\n    \u003cli\u003eSensor Module: MPD infrared carbon dioxide sensor calibrated for 0 to 5 percent volume.\u003c\/li\u003e\n    \u003cli\u003eHardware Included: Integrated mounting lugs and standard factory documentation.\u003c\/li\u003e\n    \u003cli\u003eCourier Partners: Fast global shipping utilizes Fedex, UPS, and DHL delivery services.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch2\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h2\u003e\n  \u003cp\u003eTechnical support engineers answer common operational questions regarding transmitter configuration and maintenance procedures. Plant operators review these technical inquiries to optimize gas detection performance and troubleshooting efficiency. Clear guidelines help technical staff maintain system reliability over years of service.\u003c\/p\u003e\n  \u003cul\u003e\n    \u003cli\u003eQuestion: What gases does this specific transmitter model detect? Answer: The unit detects carbon dioxide within a zero to five percent volume range using an infrared sensor.\u003c\/li\u003e\n    \u003cli\u003eQuestion: How do technicians configure the output signal? Answer: Technicians configure the standard HART communication protocol overlaid on a four to 20 milliamp output loop.\u003c\/li\u003e\n    \u003cli\u003eQuestion: What storage conditions protect the sensor during warehouse holding? Answer: Store the equipment between minus 40 degrees Celsius and 75 degrees Celsius in non-condensing humidity.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch2\u003e\u003cstrong\u003eModel Selection Comparison and Technical Advice\u003c\/strong\u003e\u003c\/h2\u003e\n  \u003cp\u003eEngineering teams frequently compare similar transmitter variants to select the optimal configuration for specific site requirements. Reviewing related product options ensures complete compatibility with existing plant control networks and safety monitoring architectures. Technical advisors recommend evaluating gas types before finalizing procurement orders.\u003c\/p\u003e\n  \u003cul\u003e\n    \u003cli\u003eAlternative Model: Compare with the \u003ca href=\"https:\/\/www.ubestplc.com\/products\/honeywell-xnx-amav-nhic1-co2-gas-detector\"\u003eHoneywell XNX-AMAV-NHIC1 CO2 Gas Detector\u003c\/a\u003e for alternative certification requirements.\u003c\/li\u003e\n    \u003cli\u003eSelection Advice: Verify operating voltage, communication protocols, and hazardous area classifications prior to purchase.\u003c\/li\u003e\n    \u003cli\u003eTechnical Support: Contact engineering sales to confirm sensor compatibility for specialized industrial gas applications.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch2\u003e\u003cstrong\u003eProduct Manual and Technical Documentation\u003c\/strong\u003e\u003c\/h2\u003e\n  \u003cp\u003eEngineering personnel download official technical manuals to review detailed wiring diagrams and configuration instructions. Accessing manufacturer documentation ensures compliance with local safety standards and correct operational setup. Plant technicians rely on these comprehensive guides during routine maintenance cycles.\u003c\/p\u003e\n  \u003cul\u003e\n    \u003cli\u003eManual Download: Access the official \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/XNX_Universal_Transmitter.pdf?v=1787797330\"\u003eXNX Universal Transmitter PDF Manual\u003c\/a\u003e for complete wiring guides.\u003c\/li\u003e\n    \u003cli\u003eDocumentation Content: Manual includes calibration steps, troubleshooting tables, and safety certification details.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003cp\u003e\u003cstrong\u003e© 2026 \u003ca href=\"https:\/\/www.ubestplc.com\/\"\u003eUbest Automation Limited\u003c\/a\u003e. \u003ca href=\"https:\/\/www.ubestplc.com\/\"\u003ehttps:\/\/www.ubestplc.com\/\u003c\/a\u003e All rights reserved.\u003c\/strong\u003e\u003cbr\u003e\n  \u003cstrong\u003eContact: Email \u003ca href=\"mailto:sales@ubestplc.com\"\u003esales@ubestplc.com\u003c\/a\u003e Phone \u003ca href=\"https:\/\/wa.me\/8618030005825\"\u003e+86 180 3000 5825\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52784632693018,"sku":"XNX-UTSV-NNIC1","price":139.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/XNX-AMSE-NHNNN_7_a6172872-3bc4-45e3-a710-37c3643a86e4.jpg?v=1788401937","url":"https:\/\/www.ubestplc.com\/products\/honeywell-xnx-utsv-nnic1-gas-detector-buy-gas-transmitter-inquiry","provider":"Ubest Automation Limited","version":"1.0","type":"link"}