{"product_id":"honeywell-xnxxsc1ss-co-gas-sensor-cartridge-technical-data","title":"Honeywell XNXXSC1SS CO Gas Sensor Cartridge Technical Data","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell XNXXSC1SS Carbon Monoxide Gas Sensor Cartridge\u003c\/strong\u003e\u003c\/h2\u003e\n\n\u003cp\u003eHoneywell engineered the \u003cstrong\u003eXNXXSC1SS\u003c\/strong\u003e sensor cartridge to deliver reliable carbon monoxide detection across tough process conditions. Plant technicians gain high operational stability through strict accuracy tolerances and swift response performance during critical gas leaks.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e \u003cspan style=\"color: #0056b3;\"\u003eHoneywell\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong\u003eXNXXSC1SS\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTarget Gas:\u003c\/strong\u003e Carbon Monoxide (CO)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSelectable Full Scale Range:\u003c\/strong\u003e 100ppm to 500ppm (default setting at 300ppm)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMeasurement Increments:\u003c\/strong\u003e 100ppm steps\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLower Detectable Limit:\u003c\/strong\u003e 5ppm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAccuracy Rating:\u003c\/strong\u003e \u003cspan style=\"color: #28a745;\"\u003e\u0026lt; +\/-2ppm\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eResponse Time (T50):\u003c\/strong\u003e \u003cspan style=\"color: #d9534f;\"\u003e\u0026lt; 15 seconds\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eResponse Time (T90):\u003c\/strong\u003e \u003cspan style=\"color: #d9534f;\"\u003e\u0026lt; 30 seconds\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSelectable Calibration Range:\u003c\/strong\u003e 30% to 70% of selected full scale range\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDefault Calibration Point:\u003c\/strong\u003e 100ppm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Temperature Range:\u003c\/strong\u003e \u003cspan style=\"color: #0056b3;\"\u003e-40°C to 55°C (-40°F to 131°F)\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental Resistance:\u003c\/strong\u003e High tolerance against rapid ambient temperature shifts and extreme outdoor exposure\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInterference Resistance:\u003c\/strong\u003e Advanced cell design minimizes cross-sensitivity to common industrial background gases\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModel Number Suffix Structure:\u003c\/strong\u003e\n    \u003cul\u003e\n      \u003cli\u003eXNX\n        \u003cul\u003e\n          \u003cli\u003e└─ Universal Transmitter Platform Series\u003c\/li\u003e\n          \u003cli\u003e└─ S\n            \u003cul\u003e\n              \u003cli\u003e└─ Electrochemical Sensor Input Type\u003c\/li\u003e\n              \u003cli\u003e└─ C1\n                \u003cul\u003e\n                  \u003cli\u003e└─ Carbon Monoxide (CO) Detection Module\u003c\/li\u003e\n                  \u003cli\u003e└─ SS\n                    \u003cul\u003e\n                      \u003cli\u003e└─ 316 Stainless Steel Heavy-Duty Housing\u003c\/li\u003e\n                    \u003c\/ul\u003e\n                  \u003c\/li\u003e\n                \u003c\/ul\u003e\n              \u003c\/li\u003e\n            \u003c\/ul\u003e\n          \u003c\/li\u003e\n        \u003c\/ul\u003e\n      \u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003eTechnicians must isolate local system power before mounting the \u003cstrong\u003eXNXXSC1SS\u003c\/strong\u003e cartridge into the transmitter socket.\u003c\/li\u003e\n  \u003cli\u003eOperators should align keying slots carefully to protect internal pin connectors from bending or mechanical damage.\u003c\/li\u003e\n  \u003cli\u003eEngineers must thread the sensor head firmly to maintain proper environmental sealing against dirt and moisture.\u003c\/li\u003e\n  \u003cli\u003eMaintenance teams apply span gas within 30% to 70% range to verify internal alarm thresholds after startup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003ePackage Contents \u0026amp; Logistics\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003eStandard factory package contains one factory-tested sensor module inside sealed protective packaging.\u003c\/li\u003e\n  \u003cli\u003eIncluded anti-static wrapping safeguards sensitive internal electronics from electrical discharges during transit.\u003c\/li\u003e\n  \u003cli\u003eShipment options include expedited door-to-door delivery via DHL courier services worldwide.\u003c\/li\u003e\n  \u003cli\u003eLogistics support includes full international transport options through FedEx express ground and air networks.\u003c\/li\u003e\n  \u003cli\u003eGlobal distribution partners provide fast order fulfillment through reliable UPS air transport logistics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWhat default detection span does this module use out of the box?\u003c\/strong\u003e\n    \u003cul\u003e\n      \u003cli\u003eHoneywell pre-sets this cartridge to a standard 300ppm span with 100ppm default calibration points.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHow fast does the unit report sudden gas concentration spikes?\u003c\/strong\u003e\n    \u003cul\u003e\n      \u003cli\u003eThe internal sensing element achieves a T50 response within 15 seconds for rapid hazard alerts.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCan field operators reconfigure the full scale measuring range later?\u003c\/strong\u003e\n    \u003cul\u003e\n      \u003cli\u003eTechnicians can select custom detection limits between 100ppm and 500ppm in convenient 100ppm increments.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eProduct Summary\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003eThe Honeywell \u003cstrong\u003eXNXXSC1SS\u003c\/strong\u003e cartridge delivers exceptional electrochemical CO monitoring across extreme industrial temperature ranges. Engineering teams rely on its rugged 316 stainless steel housing and precise under-30-second response timing to keep facilities safe.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003e© 2026 Ubest Automation Limited. \u003ca href=\"https:\/\/www.ubestplc.com\/\" target=\"_blank\"\u003ehttps:\/\/www.ubestplc.com\/\u003c\/a\u003e All rights reserved.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eContact: Email \u003ca href=\"mailto:sales@ubestplc.com\"\u003esales@ubestplc.com\u003c\/a\u003e Phone \u003ca href=\"https:\/\/wa.me\/8618030005825\" target=\"_blank\"\u003e+86 86 180 3000 5825\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52710190481690,"sku":"XNXXSC1SS","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/XNXXSC1SS.jpg?v=1787019294","url":"https:\/\/www.ubestplc.com\/products\/honeywell-xnxxsc1ss-co-gas-sensor-cartridge-technical-data","provider":"Ubest Automation Limited","version":"1.0","type":"link"}