{"product_id":"honeywell-xnxxsh2ss-h2s-gas-sensor-for-industrial-safety","title":"Honeywell XNXXSH2SS H2S Gas Sensor for Industrial Safety","description":"\u003ch2\u003e\u003cb\u003eHoneywell XNXXSH2SS Hydrogen Sulfide Sensor Guide\u003c\/b\u003e\u003c\/h2\u003e\n\n\u003ch3\u003e\u003cb\u003eExecutive Summary and Core Value\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003eIndustrial plants require dependable gas sensors for worker safety.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cb\u003eHoneywell\u003c\/b\u003e builds the \u003cb\u003e\u003cspan style=\"color: #c0392b;\"\u003eXNXXSH2SS\u003c\/span\u003e\u003c\/b\u003e sensor to detect toxic hydrogen sulfide gas.\u003c\/li\u003e\n    \u003cli\u003eSafety engineers choose this reliable unit for extreme industrial environments.\u003c\/li\u003e\n    \u003cli\u003eFacilities protect personnel effectively by deploying this precision monitoring device.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003ePrimary Technical Specifications\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003eBrand: \u003cb\u003eHoneywell\u003c\/b\u003e\n\u003c\/li\u003e\n    \u003cli\u003eModel: \u003cb\u003e\u003cspan style=\"color: #c0392b;\"\u003eXNXXSH2SS\u003c\/span\u003e\u003c\/b\u003e\n\u003c\/li\u003e\n    \u003cli\u003eProduct Type: Hydrogen Sulfide Sensor\u003c\/li\u003e\n    \u003cli\u003eTarget Gas: Hydrogen Sulfide (H2S)\u003c\/li\u003e\n    \u003cli\u003eMeasurement Range: 50 to 500 ppm full scale\n        \u003cul\u003e\n            \u003cli\u003eDefault Range: 100 ppm standard setting\u003c\/li\u003e\n            \u003cli\u003eLower Detectable Limit: 1 ppm threshold\u003c\/li\u003e\n            \u003cli\u003eResolution Steps: 10 ppm increments\u003c\/li\u003e\n        \u003c\/ul\u003e\n    \u003c\/li\u003e\n    \u003cli\u003eCalibration Gas Range: 30 to 70 percent of full scale\n        \u003cul\u003e\n            \u003cli\u003eDefault Calibration Point: 50 ppm level\u003c\/li\u003e\n        \u003c\/ul\u003e\n    \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003ePerformance Metrics and Environmental Limits\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003eResponse Time T50: Less than 20 seconds\u003c\/li\u003e\n    \u003cli\u003eResponse Time T90: Less than 30 seconds\u003c\/li\u003e\n    \u003cli\u003eMeasurement Accuracy: Plus or minus 5 ppm limit\u003c\/li\u003e\n    \u003cli\u003eOperating Temperature: Minus 40 degrees Celsius to 55 degrees Celsius\n        \u003cul\u003e\n            \u003cli\u003eEnvironmental Tolerance: High humidity and harsh industrial resistance\u003c\/li\u003e\n            \u003cli\u003eSignal Linearity: Direct proportional linear output response\u003c\/li\u003e\n            \u003cli\u003eInterference Immunity: High resistance to common plant chemical gases\u003c\/li\u003e\n            \u003cli\u003eSensitivity Rating: High signal output per ppm gas concentration\u003c\/li\u003e\n        \u003c\/ul\u003e\n    \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eInstallation Guidelines and Setup Steps\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003eTechnicians turn off system power before opening the sensor housing.\u003c\/li\u003e\n    \u003cli\u003eMaintenance staff remove the old unit from the mounting base.\u003c\/li\u003e\n    \u003cli\u003eUsers insert the replacement sensor firmly into the matching socket.\u003c\/li\u003e\n    \u003cli\u003eEngineers calibrate the device using standard test gas mixtures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003ePackage Contents and Delivery Options\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003ePackage Contents:\n        \u003cul\u003e\n            \u003cli\u003eOne hydrogen sulfide sensing module\u003c\/li\u003e\n            \u003cli\u003eProtective installation cap\u003c\/li\u003e\n            \u003cli\u003eQuick setup reference sheet\u003c\/li\u003e\n        \u003c\/ul\u003e\n    \u003c\/li\u003e\n    \u003cli\u003eShipping Carriers:\n        \u003cul\u003e\n            \u003cli\u003eFedEx express air delivery\u003c\/li\u003e\n            \u003cli\u003eUPS global freight services\u003c\/li\u003e\n            \u003cli\u003eDHL international priority shipping\u003c\/li\u003e\n        \u003c\/ul\u003e\n    \u003c\/li\u003e\n    \u003cli\u003eWarranty Terms:\n        \u003cul\u003e\n            \u003cli\u003eTwelve months standard manufacturer warranty included\u003c\/li\u003e\n        \u003c\/ul\u003e\n    \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eFrequently Asked Questions\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003eWhat is the primary gas detected by this device?\n        \u003cul\u003e\n            \u003cli\u003eHydrogen sulfide gas\u003c\/li\u003e\n        \u003c\/ul\u003e\n    \u003c\/li\u003e\n    \u003cli\u003eHow often should technicians test the sensor response?\n        \u003cul\u003e\n            \u003cli\u003eOperators perform gas tests every three months under normal conditions.\u003c\/li\u003e\n        \u003c\/ul\u003e\n    \u003c\/li\u003e\n    \u003cli\u003eCan this module operate in freezing outdoor environments?\n        \u003cul\u003e\n            \u003cli\u003eThe sensor functions properly down to minus forty degrees Celsius.\u003c\/li\u003e\n        \u003c\/ul\u003e\n    \u003c\/li\u003e\n    \u003cli\u003eWhat tool adjusts the calibration gas values?\n        \u003cul\u003e\n            \u003cli\u003eTechnicians use standard compatible control transmitters for adjustments.\u003c\/li\u003e\n        \u003c\/ul\u003e\n    \u003c\/li\u003e\n    \u003cli\u003eDoes the package include calibration adapters?\n        \u003cul\u003e\n            \u003cli\u003ePackage contents include the core sensing module and protective caps only.\u003c\/li\u003e\n        \u003c\/ul\u003e\n    \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cb\u003e© 2026 Ubest Automation Limited. \u003ca href=\"https:\/\/www.ubestplc.com\/\"\u003ehttps:\/\/www.ubestplc.com\/\u003c\/a\u003e All rights reserved.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eContact: Email \u003ca href=\"mailto:sales@ubestplc.com\"\u003esales@ubestplc.com\u003c\/a\u003e Phone \u003ca href=\"https:\/\/wa.me\/8618030005825\"\u003e+86 180 3000 5825\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52710209978650,"sku":"XNXXSH2SS","price":326.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/XNXXSH2SS.jpg?v=1787019294","url":"https:\/\/www.ubestplc.com\/products\/honeywell-xnxxsh2ss-h2s-gas-sensor-for-industrial-safety","provider":"Ubest Automation Limited","version":"1.0","type":"link"}