{"product_id":"ic695alg608-ge-fanuc-rx3i-analog-input-module","title":"IC695ALG608 | GE Fanuc | RX3i Analog Input Module","description":"\u003ch2\u003eNon-Isolated Differential Analog Voltage\/Current Input Module IC695ALG608\u003c\/h2\u003e\u003cp\u003eThe \u003cstrong\u003eIC695ALG608\u003c\/strong\u003e module provides 8 single-ended or 4 differential input channels. These analog input modules can be configured for various ranges including current (0 to 20mA, 4 to 20mA, +\/- 20mA) and voltage (+\/- 10V, 0 to 10V, +\/- 5V, 0 to 5V, 1 to 5V). They are compatible with Box-style, Extended Box-style, Spring-style, or Extended Spring-style terminal blocks, with extended terminal blocks accommodating shielded wiring.\u003c\/p\u003e\u003ch3\u003eModule Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCompletely software-configurable, no module jumpers to set\u003c\/li\u003e\n\u003cli\u003eFull autocalibration\u003c\/li\u003e\n\u003cli\u003eOn-board error-checking\u003c\/li\u003e\n\u003cli\u003eOpen-circuit detection for all voltage and 4-20mA inputs\u003c\/li\u003e\n\u003cli\u003eConfigurable scaling and offsets per channel\u003c\/li\u003e\n\u003cli\u003eHigh\/low alarm detection and reporting selectable per channel\u003c\/li\u003e\n\u003cli\u003eModule fault reporting\u003c\/li\u003e\n\u003cli\u003eSupports diagnostic point fault contacts in the logic program\u003c\/li\u003e\n\u003cli\u003eFlash memory for future upgrades\u003c\/li\u003e\n\u003cli\u003ePositive and negative Rate of Change Alarms\u003c\/li\u003e\n\u003cli\u003eAutocalibration at startup\u003c\/li\u003e\n\u003cli\u003eConfigurable interrupts for channel alarms and faults\u003c\/li\u003e\n\u003cli\u003eTerminal Block insertion or removal detection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications: IC695ALG608\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Ranges:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eCurrent: 0 to 20mA, 4 to 20mA, +\/- 20mA\u003c\/li\u003e\n\u003cli\u003eVoltage: +\/- 10V, 0 to 10V, +\/- 5V, 0 to 5V, 1 to 5V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Power Requirements:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eALG608: 330 mA maximum @ 5.0V, 600 mA maximum @ 3.3V\u003c\/li\u003e\n\u003cli\u003eALG616: 450 mA maximum @ 5.0V, 600 mA maximum @ 3.3V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCPU Version:\u003c\/strong\u003e RX3i CPU firmware version 3.0 and later\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgrammer Version:\u003c\/strong\u003e Machine Edition version 5.0 SP3 and later\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Dissipation within Module:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eIC695ALG608: 4.83 watts maximum\u003c\/li\u003e\n\u003cli\u003eIC695ALG616: 6.48 watts maximum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Derating:\u003c\/strong\u003e None\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 24 bit ADC converted to Floating Point or Integer\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Data Format:\u003c\/strong\u003e Configurable as floating point IEEE 32 bit or 16-bit integer in a 32-bit field\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFilter Options:\u003c\/strong\u003e 8Hz, 12Hz, 16Hz, 40Hz, 200Hz, 500Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Scan Time:\u003c\/strong\u003e Depends on the number of acquisition cycles in the scan and the configured filter option\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e \u0026gt;100 Kohm voltage inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Input Resistance:\u003c\/strong\u003e 249 ohms +\/- 1%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen Circuit Detection Time:\u003c\/strong\u003e 1 second maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvervoltage:\u003c\/strong\u003e +\/-60 VDC continuous, maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvercurrent:\u003c\/strong\u003e +\/-28mA continuous, maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormal Mode Noise Rejection:\u003c\/strong\u003e 500 Hz: 0.0 dB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon Mode Noise Rejection:\u003c\/strong\u003e 120dB minimum @ 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-Channel DC Crosstalk:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eSingle ended mode: -80 dB minimum\u003c\/li\u003e\n\u003cli\u003eDifferential mode, grounded common: -80 dB minimum\u003c\/li\u003e\n\u003cli\u003eDifferential mode, floating common: -60 dB minimum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibrated Accuracy:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e@ 13°C – 33°C with 8 Hz, 12 Hz, and 16 Hz filter: varies depending on range\u003c\/li\u003e\n\u003cli\u003e@ 0°C – 60°C with 8 Hz, 12 Hz, and 16 Hz filter: varies depending on range\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration Interval:\u003c\/strong\u003e 12 months typical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Voltage terminal block to backplane\/chassis:\u003c\/strong\u003e Opto-isolated, transformer isolated 250 VAC continuous\/1500 VAC for 1 minute\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":49021928243482,"sku":"IC695ALG608","price":700.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/IC695ALG608_4.jpg?v=1717163466","url":"https:\/\/www.ubestplc.com\/products\/ic695alg608-ge-fanuc-rx3i-analog-input-module","provider":"Ubest Automation Limited","version":"1.0","type":"link"}