Prosoft MVI56-MCM Modbus Master/Slave Communication Module
UBEST – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Overview
The MVI56-MCM Modbus Master/Slave Communication Module allows Rockwell Automation® ControlLogix® processors to interface easily with other Modbus protocol compatible devices. It acts as an Options module between the Modbus network and the ControlLogix backplane. Compatible devices include Modicon® PLCs and a wide range of process and control devices. Many SCADA packages also support the Modbus protocol.
Features and Benefits
-
Licensed Backplane Technology:
- Manufactured under license from Rockwell Automation®.
- High-speed data transfer between MVI56 module and ControlLogix processor.
- Installs as a Generic 1756 module, with sample ladder logic included.
- Module data and status visible in RSLogix™ 5000 controller tags.
-
Modbus Slave Protocol Interface:
- Emulates Modbus slave devices on individually-configurable application ports.
- Supports Modbus RTU and Modbus ASCII protocol versions.
- Supports floating-point data movement, including Enron, Daniel®, and other implementations.
- Suitable for SCADA and field device interface applications.
-
Easy to Configure and Monitor:
- Configuration and monitoring in RSLogix.
- LED diagnostics for quick health checks.
- Menu-driven hardware and protocol diagnostics.
- Module database accessible through serial connection to desktop PC.
-
Backed by ProSoft Technology:
- 20-year history of delivering high-quality, reliable solutions.
- Free, unlimited, worldwide Technical Support by phone.
- Three-Year Warranty ensures reliability.
- Free ProSoft software tools for seamless integration.
General Specifications
-
Single Slot - 1756 Backplane Compatible:
- Can be installed in local or remote racks.
- Recognized as an Input/Output module with access to processor memory for data transfer.
- Uses ladder logic for data transfer, with user-defined ladder configuration.
Modbus Master/Slave Communication Parameters
- Baud rate: 110 to 115K baud.
- Stop bits: 1 or 2.
- Data size: 7 or 8 bits.
- Parity: None, Even, Odd.
- RTS timing delays: 0 to 65535 milliseconds.
Modbus Function Codes Supported
- Read Coil Status
- Read Input Status
- Read Holding Registers
- Read Input Registers
- Write Single Coil
- Write Single Holding Register
- Diagnostics (Slave Only)
- Write Multiple Coils
- Write Multiple Holding Registers
- Report Slave ID (Slave Only)
- Mask Write Holding Register (Slave Only)
- Read/Write Holding Registers (Slave Only)
Functional Specifications
Modbus Master
- Configured as a virtual Modbus Master for actively issuing commands to other nodes.
- Up to 100 commands per Master port, fully configurable.
Modbus Slave
- Configured as a Modbus slave to allow remote Masters to interact with module data.
- Node address selectable from 1 to 247.
- Error codes, counters, and port status available per configured slave port.
Hardware Specifications
- Backplane Current Load: 800 mA @ 5 Vdc, 3 mA @ 24 Vdc.
- Operating Temperature: 0°C to 60°C (32°F to 140°F).
- Storage Temperature: -40°C to 85°C (-40°F to 185°F).
- Shock: 30 g operational, 50 g non-operational.
- Vibration: 5 g from 10 Hz to 150 Hz.
- Relative Humidity: 5% to 95% (without condensation).
LED Indicators
- Module Status
- Backplane Transfer Status
- Application Status
- Serial Activity
Debug/Configuration Port (CFG)
- RJ45 (DB-9M with supplied cable), RS-232 only.
Application Ports (PRT1 & PRT2)
Full hardware handshaking control.
Software configurable communication parameters.
Baud rate: 110 to 115,200 baud.
RS-232, RS-485, and RS-422 support.
Parity: None, Odd, Even.
Data bits: 5, 6, 7, or 8.
Stop bits: 1 or 2.
RTS on/off delay: 0 to 65535 milliseconds.
Optical isolation from backplane.
Shipped with: RJ45 to DB-9M cables for each port, 6-foot RS-232 configuration cable.