{"product_id":"schneider-electric-quantum-power-supply-140cps42400","title":"Schneider Electric Quantum - Power Supply 140CPS42400","description":"\u003ch2\u003eSchneider Electric 140CPS42400 Quantum Power Supply\u003c\/h2\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #2e86ab;\"\u003eSchneider Electric 140CPS42400\u003c\/span\u003e delivers robust DC power for critical Modicon Quantum automation systems. This redundant power supply module ensures continuous operation in demanding industrial environments.\u003c\/p\u003e\n\u003ch3\u003eElectrical Specifications \u0026amp; Performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Schneider Electric\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cspan style=\"color: #2e86ab;\"\u003e\u003cstrong\u003e140CPS42400\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Line:\u003c\/strong\u003e Modicon Quantum Automation Platform\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e 48-60 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Current:\u003c\/strong\u003e 3800 mA maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Current:\u003c\/strong\u003e 14 A at 40 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e 5.1 V DC regulated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current:\u003c\/strong\u003e 8 A redundant configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Interruption Tolerance:\u003c\/strong\u003e 13 ms at 48 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse Requirement:\u003c\/strong\u003e 2 A time-lag type\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e 17.2 W typical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency Rating:\u003c\/strong\u003e \u0026gt;85% at full load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Regulation:\u003c\/strong\u003e ±1% line and load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRipple and Noise:\u003c\/strong\u003e \u0026lt;50 mV peak-to-peak\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProtection \u0026amp; Safety Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInternal overvoltage protection on all outputs\u003c\/li\u003e\n\u003cli\u003eComprehensive overload and short-circuit protection\u003c\/li\u003e\n\u003cli\u003e4 kV contact electrostatic discharge immunity\u003c\/li\u003e\n\u003cli\u003e8 kV air discharge ESD protection\u003c\/li\u003e\n\u003cli\u003eElectromagnetic field resistance 9.1 V\/m 80-2000 MHz\u003c\/li\u003e\n\u003cli\u003eAlarm output contact: 1 NC 6A 220V power supply fault\u003c\/li\u003e\n\u003cli\u003eGreen LED indicator for power status monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to +60°C (32°F to 140°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to +85°C (-40°F to 185°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e 95% maximum non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Altitude:\u003c\/strong\u003e Up to 5000 meters (16404 feet)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Method:\u003c\/strong\u003e Convection cooled, no fan required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration Resistance:\u003c\/strong\u003e 2G operational, 5G non-operational\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Integration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSimple mounting in Quantum rack system\u003c\/li\u003e\n\u003cli\u003eHot-swappable design for maintenance flexibility\u003c\/li\u003e\n\u003cli\u003eStandard module format for easy replacement\u003c\/li\u003e\n\u003cli\u003eCE marked for European compliance\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No 142 and UL 508 certified\u003c\/li\u003e\n\u003cli\u003ecUL listed for Canadian market approval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackaging \u0026amp; Shipping\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Type:\u003c\/strong\u003e Individual Unit (PCE)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnits per Package:\u003c\/strong\u003e 1 power supply module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Dimensions:\u003c\/strong\u003e 12.28\" × 1.77\" × 6.42\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e 29.7 oz (843 grams)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 1.43 lb (0.65 kg)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Carriers:\u003c\/strong\u003e FedEx, UPS, DHL available\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Period:\u003c\/strong\u003e 12 months comprehensive coverage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat does redundant power supply mean for this module?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eThe \u003cstrong\u003e140CPS42400\u003c\/strong\u003e can operate in parallel with another unit to provide backup power if one supply fails, ensuring system continuity.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHow does the power interruption tolerance benefit my system?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eThe 13ms hold-up time allows the system to ride through brief power dips without shutting down critical processes.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWhat type of fuse should I use with this power supply?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eYou must use a 2 amp time-lag fuse to properly protect the input circuit and handle the initial inrush current.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCan this power supply operate in high temperature environments?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eYes, it maintains full performance across the entire industrial temperature range from 0°C to 60°C.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWhat certifications does this power supply carry for safety?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eThe module holds CE marking, cUL listing, and complies with CSA C22.2 No 142 and UL 508 standards for industrial equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2025 Ubest Automation Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.ubestplc.com\/\"\u003ehttps:\/\/www.ubestplc.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@ubestplc.com\"\u003esales@ubestplc.com\u003c\/a\u003e Phone: \u003ca href=\"https:\/\/wa.me\/8618030005825\"\u003e+86 180 3000 5825\u003c\/a\u003e\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":51262880284954,"sku":"140CPS42400","price":173.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/140CPS42400.jpg?v=1761802936","url":"https:\/\/www.ubestplc.com\/products\/schneider-electric-quantum-power-supply-140cps42400","provider":"Ubest Automation Limited","version":"1.0","type":"link"}