Schneider Electric TM218LDAE24DRHN Modicon M218 PLC
Manufacturer:
Schneider
Product No.:
TM218LDAE24DRHN
Condition:
In Stock
Product Type:
Controller Module
Product Origin:
DE
Weight:
500g
Shipping port:
Xiamen
Warranty:
12 months
UBEST – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Schneider Electric TM218LDAE24DRHN Controller Overview
Schneider Electric manufactures the TM218LDAE24DRHN programmable logic controller to automate industrial processing machines efficiently. This advanced Modicon M218 unit delivers high processing power and fast signal response for complex control tasks. Automation engineers choose the TM218LDAE24DRHN module because it handles multiple expansion modules while maintaining low power consumption.
Executive Product Summary
- This high-performance CPU base unit integrates twenty-four onboard digital channels to streamline factory automation workflows.
- The flexible controller supports up to four expansion modules to reach a maximum system capacity of one hundred fifty-two input points.
- Engineers rely on this durable processing hardware to maintain stable machine operations across wide temperature ranges.
Technical Parameters and Key Specifications
- The manufacturer Schneider Electric designs the robust Modicon M218 control platform for heavy industrial factory operations.
- The high-capacity model TM218LDAE24DRHN accepts an extended main line input voltage range from eighty-five to two hundred sixty-four volts AC.
- The internal power supply draws up to thirty-four watts while operating under full hardware electrical load conditions.
- The system hardware incorporates ten regular digital inputs alongside four high-speed counter channels for fast tracking.
- Ten heavy-duty relay outputs switch connected field loads through standard nineteen point two to twenty-eight point eight volt direct current lines.
- Standard digital input circuits feature an internal electrical resistance measurement rating of four thousand seven hundred ohms during active operation.
- High-speed counter channels feature an internal impedance rating of two thousand eight hundred ohms for fast pulse detection.
- Digital input circuits process incoming voltage signals with a fast response switching speed of two milliseconds during operation.
- High isolation barrier design withstands up to one thousand seven hundred eighty volts AC between main power circuitry and sensitive internal logic systems.
- Operating ambient temperature limits span from zero to fifty-five degrees Celsius inside typical industrial control enclosures.
- Strong industrial physical housing resists mechanical operating shocks up to fifteen peak acceleration units over eleven milliseconds.
- High structural vibration resistance rating protects delicate internal electrical parts across operating frequencies from five to one hundred fifty hertz.
- Sealed electronic packaging protects internal microprocessors against high relative humidity levels up to ninety-five percent without moisture condensation.
- The compact housing meets standard IP20 protection ratings inside clean electrical enclosure cabinets up to two thousand meters operating altitude.
Model Code Breakdown Structure
- The prefix TM218 identifies the compact Modicon M218 programmable controller series built by Schneider Electric.
- The letter L specifies the compact base logic controller architecture without internal expansion chassis components.
- The letter D confirms direct digital signal integration for discrete factory sensors and field hardware switches.
- The designation AE indicates direct wide-range alternating current line power operation for internal electronics.
- The number 24 specifies twenty-four onboard digital input and output connection terminals on the primary block.
- The letter D identifies direct current input voltage operation for all discrete field sensor connections.
- The letter R designates electromagnetic mechanical relay contact outputs for switching external motor starter units.
- The letter H indicates high-speed counting channel hardware integration for rapid pulse frequency detection.
- The suffix N marks the standard non-isolated screw terminal block connection layout for field wiring.
Core Advantages and Value Points
- The flexible control system scales up to forty-two relay outputs through external hardware expansion units.
- Integrated fast counting channels capture rapid encoder signals without requiring expensive external hardware expansion boards.
- Wide operational voltage tolerance protects internal microprocessor components against unstable main grid supply power fluctuations.
- Low operational electrical heat generation reduces cooling requirements inside closed industrial control panel cabinets.
Installation and Mounting Guidelines
- Technicians mount the main unit onto standard thirty-five millimeter DIN rails inside protective metal enclosures.
- Operators must maintain at least five meters of shielded cable distance between connected high-speed counting devices.
- Maintenance teams secure proper protective earth wiring connections before applying main line electrical input power.
Packaging Details and Logistics Service
- The factory package contains one primary controller module weighing seven hundred twenty-six total shipping grams.
- Package dimensions measure nine point six centimeters high by twelve point nine centimeters wide by eighteen point four centimeters long.
- We ship all ordered automation products globally through rapid express couriers FedEx, UPS, and DHL.
- Every automation hardware unit includes a comprehensive twelve-month quality warranty coverage period for buyers.
Frequently Asked Questions
- What maximum inrush current level does the main power supply draw during cold start conditions?
- The main internal power supply draws thirty amperes at one hundred ten volts AC and sixty amperes at two hundred forty volts AC.
- How many total I/O channels can engineers expand this compact logic controller unit to support?
- Engineers can connect up to four expansion modules to expand system capacity to one hundred fifty-two total I/O points.
- What power interruption limit does the internal main power supply tolerate before system shutdown?
- The internal main power supply tolerates power interruption times up to ten milliseconds at one hundred volts AC supply.
- What storage environment limits must warehouse teams maintain for this logic controller unit?
- Warehouse teams must store the unit between minus twenty-five and seventy degrees Celsius under three thousand meters storage altitude.
- What continuous output power level does the internal power unit deliver to attached expansion components?
- The internal continuous power supply delivers up to twenty-five watts to power downstream control expansion components.
- © 2026 Ubest Automation Limited. https://www.ubestplc.com/ All rights reserved.
- Contact: Email sales@ubestplc.com Phone +86 86 180 3000 5825