Schneider OTB1S0DM9LP Advantys OTB I/O Module – Get Quote
UBEST – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
OTB1S0DM9LP Advantys OTB Distributed I/O Module — 20 I/O with Modbus Serial
The OTB1S0DM9LP is a distributed I/O module from the Schneider Electric Advantys OTB series. It acts as a Modbus serial slave, not a programmable controller. The module packs 12 digital inputs, 8 digital outputs, two high-speed counters, and two pulse generators into a slim 55 mm housing. Engineers use it to add remote I/O near machines and cut long field wiring runs. It supports up to seven TM2 expansion modules, so you can scale I/O without a new rack.
Summary
- The OTB1S0DM9LP is a bus coupler and distributed I/O slave for Modbus RS-485 networks.
- It offers 12 digital inputs and 8 digital outputs, mixing solid-state and relay types.
- Two 20 kHz counters and two 7 kHz pulse outputs handle fast position and motion tasks.
- The module runs on 24 V DC with 19 W power consumption and a 700 mA bus current.
- Schneider Electric lists this model as discontinued, with TM3 I/O as the recommended path.
Key Selling Points
- Compact footprint: 90 × 55 × 70 mm saves panel space on crowded machines.
- Mixed output stage: 2 solid-state PNP outputs at 0.3 A plus 6 relay outputs at 2 A.
- Flexible inputs: 12 channels accept sink or source wiring to match existing panels.
- Built-in counters: 2 × 20 kHz counters cover encoder and fast event capture.
- Pulse generation: 2 × 7 kHz outputs drive simple stepper and positioning tasks.
- Easy expansion: Up to 7 TM2 modules extend I/O without extra communication hardware.
Technical Specifications
- Brand: Schneider Electric
- Model: OTB1S0DM9LP
- Series: Advantys OTB
- Device type: Bus coupler / distributed I/O slave
- Digital inputs: 12, 24 V DC, sink/source, Type 1 per IEC 61131-2
- Digital outputs: 8 total (2 solid-state PNP 0.3 A + 6 relay 2 A)
- Analog I/O: None
- High-speed counters: 2 × 20 kHz
- Pulse outputs: 2 × 7 kHz pulse generator
- Expansion capacity: Up to 7 TM2 expansion modules
- Communication port: 1 × RS-485 terminal block
- Protocols: Modbus RTU and Modbus ASCII
- Supply voltage: 24 V DC (20.4 to 26.4 V)
- Power consumption: 19 W
- Bus current: 700 mA at 26.2 V on the supply circuit
- Operating temperature: 0 to +55 °C
- Storage temperature: −25 to +70 °C
- Relative humidity: 10 to 95%, non-condensing
- Protection rating: IP20
- Dimensions (H×W×D): 90 × 55 × 70 mm
- Weight: 0.195 kg
Input and Output Performance
- Input channels follow Type 1 characteristics, so they filter contact bounce and short pulses.
- Sink and source wiring both work, which simplifies replacement on existing machines.
- The solid-state PNP outputs switch quickly for solenoid and indicator loads.
- Relay outputs handle 2 A loads and isolate the module from inductive field spikes.
- Counter inputs reach 20 kHz, enough for most encoder and flow-meter signals.
- The pulse generator reaches 7 kHz and supports basic motion commands.
Environmental Tolerance and Noise Immunity
- The module operates from 0 to +55 °C inside a standard control cabinet.
- Storage from −25 to +70 °C covers shipping and warehouse conditions.
- Humidity from 10 to 95% non-condensing suits most industrial sites.
- The IP20 housing needs a protective enclosure against dust and water.
- RS-485 differential signaling resists common-mode noise on long cable runs.
- Separate supply and signal routing improves immunity to drive and contactor noise.
Installation Guide
- Mount the module on a 35 mm DIN rail inside the enclosure.
- Keep at least 20 mm clearance above and below for airflow.
- Wire 24 V DC supply within the 20.4 to 26.4 V range.
- Connect the RS-485 terminal block with twisted-pair cable.
- Set the Modbus node address and baud rate before you power up.
- Terminate the RS-485 line at both ends of the bus.
- Land field wires on the removable terminals and check torque.
- Add TM2 expansion modules one by one and verify each address.
Packing List
- 1 × OTB1S0DM9LP distributed I/O module
- 1 × removable terminal block set
- 1 × terminal label sheet
- 1 × installation guide
- Shipping method: FedEx, UPS, or DHL, chosen at order confirmation
FAQ
- Does the OTB1S0DM9LP work as a standalone controller? No, it operates as a bus coupler and distributed I/O slave on a Modbus network.
- Can I mix sink and source sensors on one module? Yes, the 12 digital inputs accept either sink or source wiring.
- How many TM2 modules can I attach? You can add up to 7 TM2 expansion modules to one coupler.
- Which serial protocol does the module speak? It speaks Modbus RTU and Modbus ASCII over RS-485.
- What should I do since Schneider lists this model as discontinued? Plan a migration to TM3BCEIP with TM3 distributed I/O, or secure spare stock now.
- Does the module need a separate communication module? No, the RS-485 port is built in and defines this NIM variant.
Lifecycle Note
- Schneider Electric marks this model as discontinued, last verified in September 2026.
- The Advantys OTB family remains active on EtherNet/IP, Modbus, and CANopen variants.
- Schneider recommends TM3BCEIP with TM3 distributed I/O as the replacement path.
- Buyers should confirm stock and revision before they commit to a new machine design.
© 2026 Ubest Automation Limited. https://www.ubestplc.com/ All rights reserved.
Contact: sales@ubestplc.com | +86 86 180 3000 5825