{"product_id":"schneider-tm200c40u-40-i-o-controller-request-pricing","title":"Schneider TM200C40U Logic Controller – Get a Quote Today","description":"\u003ch2\u003e\u003cstrong\u003eTM200C40U Logic Controller: 40 I\/O Transistor Sink Controller from Schneider Electric\u003c\/strong\u003e\u003c\/h2\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eTM200C40U\u003c\/strong\u003e belongs to the Easy Modicon M200 range from Schneider Electric. This logic controller delivers 40 discrete I\/O points on a 24 V DC supply. It combines fast counting inputs, high-speed transistor outputs and integrated serial links. Engineers use it for compact machine control, packaging equipment and small automation cells. The controller supports up to four expansion modules for flexible scaling.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eSummary\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eThe \u003cstrong\u003eTM200C40U\u003c\/strong\u003e offers 40 discrete I\/O with 24 V DC transistor sink outputs.\u003c\/li\u003e\n  \u003cli\u003eFour fast inputs and four high-speed inputs reach 100 kHz for HSC mode.\u003c\/li\u003e\n  \u003cli\u003eTwo fast outputs support PWM, PLS and PTO modes at 100 kHz.\u003c\/li\u003e\n  \u003cli\u003eDual serial links cover RS485 and RS232\/RS485 with Modbus RTU\/ASCII.\u003c\/li\u003e\n  \u003cli\u003eSchneider Electric builds this M200 controller for DIN rail mounting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Schneider Electric\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eTM200C40U\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Easy Modicon M200\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Logic controller with 40 discrete I\/O\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated supply:\u003c\/strong\u003e 24 V DC, operating range 20.4 to 28.8 V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDiscrete inputs:\u003c\/strong\u003e 4 fast (I2–I5), 4 high-speed (I0, I1, I6, I7), 16 regular (I8–I23)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput voltage and current:\u003c\/strong\u003e 24 V DC, 7 mA per input, 3.3 kOhm impedance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput logic:\u003c\/strong\u003e Sink or source, type 1 per EN\/IEC 61131-2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDiscrete outputs:\u003c\/strong\u003e 2 fast (Q0–Q1), 14 transistor (Q2–Q15)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput rating:\u003c\/strong\u003e 24 V DC, 0.5 A per output, negative logic (sink)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput frequency:\u003c\/strong\u003e 100 kHz in PWM\/PLS mode on Q0–Q1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eResponse time:\u003c\/strong\u003e 1 ms turn-on and turn-off for Q0–Q15\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput response:\u003c\/strong\u003e 5 µs high-speed, 35\/100 µs fast, 35\/125 µs regular\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfigurable filtering:\u003c\/strong\u003e 0 ms, 3 ms or 12 ms per input\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCommon current:\u003c\/strong\u003e 2 A at COM 0, 2 A at COM 1, 4 A at COM 2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProtection:\u003c\/strong\u003e Overload and short-circuit at 3.8 A with 1 s automatic reset\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLeakage and drop:\u003c\/strong\u003e 0.1 mA maximum leakage, under 1 V voltage drop\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTungsten load:\u003c\/strong\u003e Under 12 W for outputs and fast outputs\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBackup memory:\u003c\/strong\u003e 512 byte internal flash, optional 32 GB micro SD card\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBattery:\u003c\/strong\u003e BR2032 Li-CFx, 5-year life, 3-year backup at 25 °C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExecution speed:\u003c\/strong\u003e 0.2 µs per Boolean instruction, 0.3 ms per 1 K instructions\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEvent task response:\u003c\/strong\u003e 60 µs, clock drift within 90 s\/month at 25 °C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRegulation:\u003c\/strong\u003e Adjustable PID with up to 14 simultaneous loops\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePositioning:\u003c\/strong\u003e PWM\/PLS on 2 channels at 100 kHz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCounting:\u003c\/strong\u003e 4 HSC inputs at 100 kHz, 32 bits, quadrature x1\/x2\/x4, pulse\/direction, CW\/CCW\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated ports:\u003c\/strong\u003e USB mini B 2.0, serial 1 RS485, serial 2 RS232\/RS485\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTransmission rate:\u003c\/strong\u003e 1.2 to 115.2 kbit\/s serial, 12 Mbit\/s USB\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProtocols:\u003c\/strong\u003e Modbus master\/slave RTU\/ASCII, SoMachine-Network\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLocal signalling:\u003c\/strong\u003e LEDs for PWR, RUN, ERR, SD, BAT, SL1 and I\/O state\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExpansion:\u003c\/strong\u003e 4 modules, up to 64 relay outputs or 144 transistor outputs\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower consumption:\u003c\/strong\u003e 10 W at 24 V DC with maximum I\/O\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInrush current:\u003c\/strong\u003e 35 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInsulation:\u003c\/strong\u003e 500 V AC between input and logic, 500 V DC between supply and logic\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable distance:\u003c\/strong\u003e Under 50 m unshielded input, under 10 m shielded fast input, under 150 m output\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e TH35-15 or TH35-7.5 DIN rail per IEC 60715, or panel with fixing kit\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 90 mm height, 70 mm depth, 175 mm width\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNet weight:\u003c\/strong\u003e 0.468 kg\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProtection degree:\u003c\/strong\u003e IP20 with protective cover in place\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e 0 to 55 °C horizontal installation\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStorage temperature:\u003c\/strong\u003e -25 to 70 °C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRelative humidity:\u003c\/strong\u003e 10 to 95 % without condensation\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating altitude:\u003c\/strong\u003e 0 to 2000 m, storage up to 3000 m\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePollution degree:\u003c\/strong\u003e 2 or lower\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShock resistance:\u003c\/strong\u003e 15 gn for 11 ms and 30 gn for 6 ms\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVibration resistance:\u003c\/strong\u003e 3.5 mm at 5–8.4 Hz, 1 gn at 8.4–150 Hz on rail\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eImmunity to microbreaks:\u003c\/strong\u003e 2 ms\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEMC immunity:\u003c\/strong\u003e 8 kV air and 6 kV contact discharge per EN\/IEC 61000-4-2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eField immunity:\u003c\/strong\u003e 10 V\/m from 80 MHz to 3 GHz per EN\/IEC 61000-4-3\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBurst immunity:\u003c\/strong\u003e 2 kV power lines, 1 kV I\/O and serial link per EN\/IEC 61000-4-4\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSurge immunity:\u003c\/strong\u003e 1 kV DC lines, 1 kV I\/O per EN\/IEC 61000-4-5\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConducted RF:\u003c\/strong\u003e 10 V from 0.15 to 80 MHz per EN\/IEC 61000-4-6\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEmission:\u003c\/strong\u003e Class A radiated and conducted per EN\/IEC 55011\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN\/IEC 61131-2, EN\/IEC 61010-2-201\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e CE, RCM, IACS E10, CSA, CULus\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMount the controller on a TH35-15 or TH35-7.5 DIN rail per IEC 60715.\u003c\/li\u003e\n  \u003cli\u003eUse the fixing kit when you choose panel mounting instead of rail mounting.\u003c\/li\u003e\n  \u003cli\u003eConnect 24 V DC supply to the removable 3-terminal screw block.\u003c\/li\u003e\n  \u003cli\u003eWire inputs to the removable screw terminal block and keep polarity per sink or source logic.\u003c\/li\u003e\n  \u003cli\u003eWire outputs to the removable screw terminal block and respect the COM common current limits.\u003c\/li\u003e\n  \u003cli\u003eKeep shielded cable under 10 m for fast and high-speed inputs.\u003c\/li\u003e\n  \u003cli\u003eKeep unshielded input cable under 50 m and output cable under 150 m.\u003c\/li\u003e\n  \u003cli\u003eConnect serial 1 to RS485 and serial 2 to RS232 or RS485 through the 4-terminal block.\u003c\/li\u003e\n  \u003cli\u003eUse the mini B USB 2.0 port for the programming terminal.\u003c\/li\u003e\n  \u003cli\u003eInsert an optional 32 GB micro SD card for data storage.\u003c\/li\u003e\n  \u003cli\u003eVerify the PWR, RUN and ERR LEDs after you power up the controller.\u003c\/li\u003e\n  \u003cli\u003eRespect the 0 to 55 °C ambient range for horizontal installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003ePackage List\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x Schneider Electric \u003cstrong\u003eTM200C40U\u003c\/strong\u003e logic controller\u003c\/li\u003e\n  \u003cli\u003e1 x set of removable screw terminal blocks for inputs and outputs\u003c\/li\u003e\n  \u003cli\u003e1 x 3-terminal screw block for the 24 V DC supply\u003c\/li\u003e\n  \u003cli\u003e1 x 4-terminal screw block for the serial link\u003c\/li\u003e\n  \u003cli\u003e1 x fixing kit for panel mounting\u003c\/li\u003e\n  \u003cli\u003e1 x protective cover for IP20 protection\u003c\/li\u003e\n  \u003cli\u003e1 x quick start documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eShipping\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eWe ship orders by FedEx, UPS or DHL according to your delivery preference.\u003c\/li\u003e\n  \u003cli\u003eWe pack each controller with shock protection for safe transport.\u003c\/li\u003e\n  \u003cli\u003eWe confirm the tracking number after dispatch so you can follow the shipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQ: How many I\/O points does the TM200C40U provide?\u003c\/strong\u003e\u003cbr\u003eA: It provides 24 discrete inputs and 16 discrete outputs for a total of 40 points.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQ: Does the controller support high-speed counting?\u003c\/strong\u003e\u003cbr\u003eA: Yes, four HSC inputs reach 100 kHz with 32-bit counting in quadrature, pulse\/direction or CW\/CCW mode.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQ: Which output mode do the fast outputs use?\u003c\/strong\u003e\u003cbr\u003eA: Q0 and Q1 run in PWM, PLS or PTO mode at 100 kHz.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQ: Can I expand the I\/O capacity?\u003c\/strong\u003e\u003cbr\u003eA: Yes, you can add four expansion modules for up to 64 relay outputs or 144 transistor outputs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQ: Which serial protocols does it support?\u003c\/strong\u003e\u003cbr\u003eA: It supports Modbus master\/slave RTU\/ASCII and SoMachine-Network over RS485 and RS232\/RS485.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQ: What is the operating temperature range?\u003c\/strong\u003e\u003cbr\u003eA: The controller operates from 0 to 55 °C in horizontal installation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQ: How do I request a quotation?\u003c\/strong\u003e\u003cbr\u003eA: Email \u003ca href=\"mailto:sales@ubestplc.com\"\u003esales@ubestplc.com\u003c\/a\u003e or message us on WhatsApp at \u003ca href=\"https:\/\/wa.me\/868618030005825\"\u003e+86 86 180 3000 5825\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003e© 2026 Ubest Automation Limited. \u003ca href=\"https:\/\/www.ubestplc.com\/\"\u003ehttps:\/\/www.ubestplc.com\/\u003c\/a\u003e All rights reserved.\u003c\/strong\u003e\u003cbr\u003e\nContact: \u003ca href=\"mailto:sales@ubestplc.com\"\u003esales@ubestplc.com\u003c\/a\u003e | Phone: \u003ca href=\"https:\/\/wa.me\/868618030005825\"\u003e+86 86 180 3000 5825\u003c\/a\u003e\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":53160585527578,"sku":"TM200C40U","price":257.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/TM200C40U_3.jpg?v=1792659455","url":"https:\/\/www.ubestplc.com\/products\/schneider-tm200c40u-40-i-o-controller-request-pricing","provider":"Ubest Automation Limited","version":"1.0","type":"link"}