Schneider TM221CE16R Logic Controller – 16 I/O, Ethernet

In stock
Manufacturer:
Schneider
Product No.:
TM221CE16R
Condition:
In Stock
Product Type:
Controller
Product Origin:
FR
Weight:
350g
Shipping port:
Xiamen
Warranty:
12 months

UBEST – Trusted Global Automation Parts Supplier

We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.

About Us | Contact

TM221CE16R: Modicon M221 Logic Controller with 16 I/O, Relay Outputs and Ethernet

The TM221CE16R comes from the Modicon M221 range built by Schneider Electric. This logic controller runs on 100 to 240 V AC supply. It packs 16 discrete I/O, including 9 inputs and 7 relay outputs. Two analog inputs handle 0 to 10 V signals with 10-bit resolution. An RJ45 Ethernet port adds Modbus TCP and Ethernet/IP support. Engineers pick this model for small machines, building automation and compact process control.

Summary

  • The TM221CE16R gives you 16 I/O, relay outputs and a built-in Ethernet port.
  • It runs directly on 100 to 240 V AC mains power.
  • Two analog inputs reach 10-bit resolution with 10 mV per step.
  • Four fast counting inputs reach 100 kHz for high-speed tasks.
  • Schneider Electric designed this M221 controller for DIN rail mounting.

Top Reasons to Choose This Controller

  • Mains-ready supply: The controller accepts 100 to 240 V AC without an external power supply.
  • Built-in Ethernet: You get Modbus TCP client/server, Modbus TCP slave and Ethernet/IP adapter in one RJ45 port.
  • Flexible relay outputs: Seven normally open relays switch 5 to 125 V DC and 5 to 250 V AC at 2 A.
  • Analog sensing: Two 0 to 10 V inputs deliver 10-bit resolution and ±1 % full-scale accuracy.
  • Fast counting: Four HSC inputs run at 100 kHz with 32-bit counting capacity.
  • PID control: The controller runs up to 14 PID loops at the same time.
  • Real-time clock: A built-in RTC drifts less than 30 seconds per month at 25 °C.
  • Long relay life: Mechanical durability reaches 20 million cycles.
  • Compact footprint: The unit measures only 90 x 70 x 95 mm and weighs 0.346 kg.
  • Wide temperature range: The controller operates from -10 to 55 °C in horizontal mounting.

Technical Specifications

  • Brand: Schneider Electric
  • Model: TM221CE16R
  • Series: Modicon M221
  • Product type: Logic controller with Ethernet
  • Rated supply: 100 to 240 V AC, limits 85 to 264 V, 50/60 Hz
  • Inrush current: 40 A maximum
  • Power consumption: 33 VA without expansion, 49 VA with maximum expansion
  • Expansion bus output: 0.325 A at 5 V and 0.12 A at 24 V
  • Discrete inputs: 9 inputs per IEC 61131-2 Type 1, sink or source logic
  • Input voltage and current: 24 V DC, 7 mA regular, 5 mA fast
  • Input impedance: 3.4 kOhm regular, 4.9 kOhm fast
  • Input thresholds: State 1 at 15 V or higher, state 0 at 5 V or lower
  • Analog inputs: 2 channels, 0 to 10 V range, 10-bit resolution, 10 mV LSB
  • Analog accuracy: ±1 % of full scale, 100 kOhm impedance
  • Analog overload: ±30 V DC for 5 minutes, ±13 V DC permanent
  • Analog conversion: 1 ms per channel plus one controller cycle
  • Discrete outputs: 7 relay outputs, normally open
  • Output rating: 2 A, 5 to 125 V DC and 5 to 250 V AC
  • Output limits: 125 V DC and 277 V AC maximum
  • Common current: 6 A at COM 1, 7 A at COM 0
  • Output response: 10 ms turn-on and 10 ms turn-off
  • Input response: 5 µs fast input, 35 µs turn-on and 100 µs turn-off regular
  • Configurable filtering: 0 ms, 3 ms or 12 ms per input
  • Switching frequency: 20 operations per minute at maximum load
  • Minimum load: 1 mA at 5 V DC for relay output
  • Mechanical durability: 20 million cycles or more
  • Electrical durability: 100000 to 300000 cycles across AC and DC load types
  • Memory: 256 kB application RAM, 256 kB variable RAM, 256 kB flash backup
  • Data storage: Optional 2 GB SD card
  • Battery: BR2032 lithium, 4-year life, 1-year backup at 25 °C
  • Execution speed: 0.2 µs per Boolean instruction, 0.3 ms per 1 K instructions
  • Event task response: 60 µs
  • Object areas: 255 timers, 255 counters, 512 constant words, 512 memory bits, 8000 memory words
  • Real-time clock: Built in, drift under 30 s/month at 25 °C
  • PID loops: Up to 14 simultaneous loops
  • Counting: 4 HSC inputs at 100 kHz, 32 bits, A/B, single phase and pulse/direction modes
  • USB port: Mini B USB 2.0 at 480 Mbit/s
  • Ethernet port: RJ45, 10BASE-T/100BASE-TX, 100 m copper cable
  • Serial link: RJ45 RS232/RS485 at 1.2 to 115.2 kbit/s
  • Protocols: Modbus RTU/ASCII, Modbus TCP, Ethernet/IP, SoMachine-Network
  • Communication services: DHCP client, Modbus TCP client/server/slave, Ethernet/IP adapter
  • Sensor supply: 24 V DC at 250 mA from the controller
  • Insulation: 2300 V AC output to logic, 500 V AC input to logic, 1500 V AC supply to ground
  • Cable distance: 10 m shielded fast input, 30 m unshielded output and digital input, 1 m analog input
  • Mounting: TH35-15 or TH35-7.5 DIN rail, or panel with fixing kit
  • Dimensions: 90 mm height, 70 mm depth, 95 mm width
  • Weight: 0.346 kg
  • Protection degree: IP20 with protective cover in place
  • Operating temperature: -10 to 55 °C horizontal, -10 to 35 °C vertical
  • Storage temperature: -25 to 70 °C
  • Humidity: 10 to 95 % without condensation
  • Altitude: 0 to 2000 m operating, 0 to 3000 m storage
  • Pollution degree: 2 or lower
  • Shock resistance: 98 m/s² at 11 ms
  • Vibration resistance: 3.5 mm at 5 to 8.4 Hz, 1 gn at 8.4 to 150 Hz
  • Microbreak immunity: 10 ms
  • ESD immunity: 4 kV contact, 8 kV air per EN/IEC 61000-4-2
  • Field immunity: 10 V/m from 80 MHz to 1 GHz per EN/IEC 61000-4-3
  • Magnetic immunity: 30 A/m at 50/60 Hz per EN/IEC 61000-4-8
  • Burst immunity: 2 kV power lines and relay output, 1 kV Ethernet, serial and I/O
  • Surge immunity: 2 kV AC lines and relay output common mode, 1 kV I/O
  • Conducted RF: 10 Vrms from 0.15 to 80 MHz per EN/IEC 61000-4-6
  • Marine RF: 3 Vrms from 0.1 to 80 MHz per LR, ABS, DNV and GL rules
  • Emission: Class A radiated and conducted per EN/IEC 55011
  • Standards: EN/IEC 60664-1, EN/IEC 61010-2-201, EN/IEC 61131-2
  • Certifications: CE, RCM, DNV-GL, ABS, IACS E10, LR, EAC, CSA, cULus

Installation Guide

  • Clip the controller onto a TH35-15 or TH35-7.5 DIN rail per IEC 60715.
  • Use the fixing kit when you prefer panel mounting over rail mounting.
  • Feed 100 to 240 V AC into the 3-terminal supply block.
  • Wire discrete inputs to the removable screw block and match sink or source logic.
  • Wire relay outputs to the removable screw block and check the COM current limits.
  • Connect analog signals to the 4-terminal connector and keep cable under 1 m.
  • Keep shielded fast input cable under 10 m for reliable counting.
  • Plug the RJ45 Ethernet cable into the port and confirm the Link and ACT LEDs.
  • Connect serial 1 through the RJ45 port for RS232 or RS485 communication.
  • Use the mini B USB 2.0 port for programming and firmware updates.
  • Insert an optional 2 GB SD card for application and data storage.
  • Check the PWR, RUN and ERR LEDs after power-up.

Package List

  • 1 x Schneider Electric TM221CE16R logic controller
  • 1 x removable screw terminal block for inputs
  • 1 x removable screw terminal block for outputs
  • 1 x 3-terminal block for the AC power supply
  • 1 x 4-terminal connector for analog inputs
  • 1 x fixing kit for panel mounting
  • 1 x protective cover for IP20 protection
  • 1 x quick start documentation

Warranty and Shipping

  • We cover this controller with a 12-month warranty against manufacturing defects.
  • We ship by FedEx, UPS or DHL based on your delivery preference.
  • We pack each unit with shock protection for safe transport.
  • We send the tracking number after dispatch so you can follow the shipment.

FAQ

  • Q: Can the TM221CE16R run without a separate 24 V power supply?
    A: Yes, it runs directly on 100 to 240 V AC mains and also supplies 24 V DC at 250 mA for sensors.
  • Q: Which Ethernet services does the built-in RJ45 port support?
    A: The port supports Modbus TCP client, server and slave roles plus Ethernet/IP adapter mode.
  • Q: How many relay outputs can I expand with this controller?
    A: You can add up to four relay expansion modules or four transistor expansion modules.
  • Q: What load types can the relay outputs switch?
    A: The relays handle resistive and inductive AC and DC loads at 2 A within the 5 to 250 V AC or 5 to 125 V DC range.
  • Q: How do I request pricing or a quotation?
    A: Email sales@ubestplc.com or message us on WhatsApp at +86 86 180 3000 5825.

© 2026 Ubest Automation Limited. https://www.ubestplc.com/ All rights reserved.
Contact: sales@ubestplc.com | Phone: +86 86 180 3000 5825