{"product_id":"schneider-tsxpsy5520m-power-supply-module-modicon-premium","title":"Schneider TSXPSY5520M Power Supply Module – Modicon Premium","description":"\u003ch2\u003e\u003cstrong\u003eSchneider TSXPSY5520M Power Supply Module – Modicon Premium Platform\u003c\/strong\u003e\u003c\/h2\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eTSXPSY5520M\u003c\/strong\u003e is a power supply module from Schneider Electric for the Modicon Premium automation platform. It takes a 24 to 48 V DC input and delivers 50 W of useful secondary power. The \u003cstrong\u003eTSXPSY5520M\u003c\/strong\u003e feeds rack backplanes with a stable 5 V and 24 V DC output. It ships with full primary and secondary protection, so your PLC rack keeps running through overloads and short circuits.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eSummary\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDelivers 50 W total useful power from a compact double-format module.\u003c\/li\u003e\n\u003cli\u003eAccepts 19.2 to 60 V DC input for flexible industrial DC bus voltages.\u003c\/li\u003e\n\u003cli\u003eProtects the rack with primary fuse, overload, overvoltage and short-circuit protection.\u003c\/li\u003e\n\u003cli\u003eRuns from 0 to 60 °C with IP20 protection and pollution degree 2.\u003c\/li\u003e\n\u003cli\u003eCarries CE marking and major marine certifications for harsh sites.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eKey Selling Points\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide input window:\u003c\/strong\u003e 19.2 to 60 V DC covers 24 V and 48 V DC systems with margin.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual output rails:\u003c\/strong\u003e 5 V DC at 7 A and 24 V DC at 0.8 A serve logic and relay loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStrong inrush handling:\u003c\/strong\u003e 15 A inrush at both 24 V and 48 V avoids breaker trips.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh dielectric strength:\u003c\/strong\u003e 2000 V between primary and earth, and primary and secondary.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine ready:\u003c\/strong\u003e Certifications include DNV, LR, ABS, RINA, GL, BV and RMRS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClear status LEDs:\u003c\/strong\u003e A green OK LED and a red BAT LED show supply and battery state.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Schneider Electric\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eTSXPSY5520M\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Modicon Premium Automation platform\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Power supply module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary voltage range:\u003c\/strong\u003e 19.2 to 60 V DC, nominal 24 to 48 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput current:\u003c\/strong\u003e ≤1500 mA at 48 V, ≤3000 mA at 24 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush current:\u003c\/strong\u003e 15 A at 24 V and 15 A at 48 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI²t on activation:\u003c\/strong\u003e 50 A²·s at 24 V and 55 A²·s at 48 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIt on activation:\u003c\/strong\u003e 7 A·s at 24 V and 6 A·s at 48 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal useful secondary power:\u003c\/strong\u003e 50 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecondary power split:\u003c\/strong\u003e 19 W at 24 V DC and 35 W at 5 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecondary current:\u003c\/strong\u003e 7 A at 5 V DC and 0.8 A at 24 V DC relay supply\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary protection:\u003c\/strong\u003e Internal time-delayed fuse, 5 A, 5 x 20 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecondary protection:\u003c\/strong\u003e Overload, overvoltage and short-circuit protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e ≥10 mOhm between primary and ground, and primary and secondary\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDielectric strength:\u003c\/strong\u003e 2000 V primary to earth, 2000 V primary to secondary\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMicrobreak immunity:\u003c\/strong\u003e 1 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule format:\u003c\/strong\u003e Double\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet weight:\u003c\/strong\u003e 0.89 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eOperating Range and Environmental Resistance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e 0 to 60 °C for continuous industrial duty\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage temperature:\u003c\/strong\u003e -25 to 70 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative humidity:\u003c\/strong\u003e 10 to 95 % without condensation in operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage humidity:\u003c\/strong\u003e 5 to 95 % without condensation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating altitude:\u003c\/strong\u003e 0 to 2000 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtective treatment:\u003c\/strong\u003e TC coating for tough plant conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection degree:\u003c\/strong\u003e IP20 with pollution degree 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDielectric strength:\u003c\/strong\u003e 2000 V isolation resists spikes on harsh DC buses\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eStandards and Certifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCE marking covers the 73\/23\/EEC, 89\/336\/EEC, 92\/31\/EEC, 93\/68\/EEC directives.\u003c\/li\u003e\n\u003cli\u003eUL 508 and CSA C22.2 No 142 support industrial control panel use.\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No 213 Class I Division 2 covers Groups A, B, C and D.\u003c\/li\u003e\n\u003cli\u003eIEC 61131-2 confirms programmable controller compatibility.\u003c\/li\u003e\n\u003cli\u003eMarine approvals include RMRS, DNV, LR, ABS, RINA, GL and BV.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module in a Modicon Premium rack slot with double format space.\u003c\/li\u003e\n\u003cli\u003eWire the DC input to the primary terminals and check polarity first.\u003c\/li\u003e\n\u003cli\u003eKeep input cable short to limit voltage drop at 3000 mA draw.\u003c\/li\u003e\n\u003cli\u003eConfirm the green OK LED lights after power up.\u003c\/li\u003e\n\u003cli\u003eCheck the red BAT LED to spot battery faults early.\u003c\/li\u003e\n\u003cli\u003eLeave airflow space around the module because it dissipates heat.\u003c\/li\u003e\n\u003cli\u003eTighten terminal screws to the torque in the rack manual.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Schneider Modicon \u003cstrong\u003eTSXPSY5520M\u003c\/strong\u003e power supply module\u003c\/li\u003e\n\u003cli\u003e1 x Internal 5 A time-delayed primary fuse, fitted\u003c\/li\u003e\n\u003cli\u003e1 x Installation and wiring documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eWarranty and Shipping\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEvery unit carries a 12-month warranty from Ubest Automation.\u003c\/li\u003e\n\u003cli\u003eWe ship worldwide through FedEx, UPS and DHL.\u003c\/li\u003e\n\u003cli\u003eTracking numbers reach you once the carrier scans the parcel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What input voltage range does the TSXPSY5520M accept?\u003c\/strong\u003e\u003cbr\u003eA: It accepts 19.2 to 60 V DC, covering nominal 24 V and 48 V DC systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How much power does the module deliver to the rack?\u003c\/strong\u003e\u003cbr\u003eA: It delivers 50 W total, split as 35 W at 5 V and 19 W at 24 V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Which faults does the secondary circuit protect against?\u003c\/strong\u003e\u003cbr\u003eA: It guards against overload, overvoltage and short circuit on the secondary side.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What does the red BAT LED indicate?\u003c\/strong\u003e\u003cbr\u003eA: It signals a battery fault, so maintenance staff can replace the battery early.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does the module suit marine and hazardous locations?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it holds DNV, LR, ABS, RINA, GL, BV and RMRS approvals plus Class I Division 2 ratings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003e© 2026 Ubest Automation Limited. \u003ca href=\"https:\/\/www.ubestplc.com\/\"\u003ehttps:\/\/www.ubestplc.com\/\u003c\/a\u003e All rights reserved.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eContact: \u003ca href=\"mailto:sales@ubestplc.com\"\u003esales@ubestplc.com\u003c\/a\u003e | \u003ca href=\"https:\/\/wa.me\/868618030005825\"\u003e+86 86 180 3000 5825\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":53264800055578,"sku":"TSXPSY5520M","price":257.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/TSXPSY5520M-3.jpg?v=1792659759","url":"https:\/\/www.ubestplc.com\/products\/schneider-tsxpsy5520m-power-supply-module-modicon-premium","provider":"Ubest Automation Limited","version":"1.0","type":"link"}