{"product_id":"schneider-tsxrky12ex-12-slot-extendable-rack-get-quote","title":"Schneider TSXRKY12EX 12-Slot Extendable Rack – Get Quote","description":"\u003ch2\u003e\u003cstrong\u003eSchneider Electric TSXRKY12EX Extendable Rack – 12 Slots for Modicon Premium Multi-Rack Systems\u003c\/strong\u003e\u003c\/h2\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eTSXRKY12EX\u003c\/strong\u003e is a 12-slot extendable rack from Schneider Electric. It belongs to the Modicon Premium automation platform. Engineers use this rack to build multi-rack configurations with I\/O modules, TSXPSY power supplies, and TSXP57 processors. The unit mounts on a 35 mm DIN rail or a panel with four M6 screws. Two SUB-D 9 female connectors handle remote bus X connections between racks. The \u003cstrong\u003eTSXRKY12EX\u003c\/strong\u003e weighs 2.34 kg and carries CE marking. It operates from 0 to 60 °C and holds IP20 protection.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eSummary\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSchneider Electric builds this 12-slot extendable rack for the Modicon Premium platform.\u003c\/li\u003e\n\u003cli\u003eTwo SUB-D 9 female connectors link multiple racks over the X bus.\u003c\/li\u003e\n\u003cli\u003eThe rack accepts I\/O modules, specific application modules, TSXPSY supplies, and TSXP57 processors.\u003c\/li\u003e\n\u003cli\u003eFour M6 screws or 35 mm DIN rail clips secure the unit in a cabinet.\u003c\/li\u003e\n\u003cli\u003eThe 2.34 kg chassis supports 0 to 60 °C operation and IP20 protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eKey Selling Points\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTwelve slots give you room for dense I\/O mixes in one chassis.\u003c\/li\u003e\n\u003cli\u003eRemote bus X connectors let you spread racks across a large machine.\u003c\/li\u003e\n\u003cli\u003eThe Modicon Premium platform keeps spare parts and modules easy to source.\u003c\/li\u003e\n\u003cli\u003eDual mounting options speed up panel assembly and retrofit work.\u003c\/li\u003e\n\u003cli\u003eMarine and industrial certifications cover harsh plant environments.\u003c\/li\u003e\n\u003cli\u003eThe metal chassis resists vibration and holds module alignment over time.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Schneider Electric\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eTSXRKY12EX\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Modicon Premium Automation platform\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Extendable rack for multi-racks configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot count:\u003c\/strong\u003e 12 slots for I\/O and application modules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e I\/O modules, specific application modules, TSXPSY power supplies, TSXP57 processors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus connection:\u003c\/strong\u003e 2 female SUB-D 9 connectors for remote bus X\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFixing mode:\u003c\/strong\u003e 4 M6 screws on panel, or clips on 35 mm symmetrical DIN rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 2.34 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarking:\u003c\/strong\u003e CE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e 0 to 60 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage temperature:\u003c\/strong\u003e -25 to 70 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating humidity:\u003c\/strong\u003e 10 to 95 % without condensation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage humidity:\u003c\/strong\u003e 5 to 95 % without condensation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating altitude:\u003c\/strong\u003e 0 to 2000 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtective treatment:\u003c\/strong\u003e TC coating for tough plant air\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection degree:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePollution degree:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e IEC 61131-2, UL 508, CSA C22.2 No 142, CSA C22.2 No 213 Class I Division 2 Groups A to D\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirectives:\u003c\/strong\u003e 73\/23\/EEC, 89\/336\/EEC, 92\/31\/EEC, 93\/68\/EEC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e RINA, DNV, GL, ABS, RMRS, BV, LR\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Resistance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe TC protective treatment shields the chassis from dust and corrosive air.\u003c\/li\u003e\n\u003cli\u003eClass I Division 2 ratings cover Groups A, B, C, and D hazardous areas.\u003c\/li\u003e\n\u003cli\u003eMarine certifications from DNV, GL, ABS, LR, BV, and RMRS suit offshore cabinets.\u003c\/li\u003e\n\u003cli\u003eIP20 protection blocks finger contact with live parts inside the panel.\u003c\/li\u003e\n\u003cli\u003ePollution degree 2 suits typical factory air with light non-conductive dust.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFix the rack to a panel with four M6 screws for high-vibration machines.\u003c\/li\u003e\n\u003cli\u003eClip the rack onto a 35 mm symmetrical DIN rail for faster assembly.\u003c\/li\u003e\n\u003cli\u003eLink racks with SUB-D 9 cables on the two female bus X connectors.\u003c\/li\u003e\n\u003cli\u003eSeat TSXPSY power supplies and TSXP57 processors in the correct slots.\u003c\/li\u003e\n\u003cli\u003eKeep the cabinet between 0 and 60 °C during continuous operation.\u003c\/li\u003e\n\u003cli\u003eStay below 2000 m altitude to keep cooling performance within spec.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003ePackage List\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Schneider Electric \u003cstrong\u003eTSXRKY12EX\u003c\/strong\u003e extendable rack\u003c\/li\u003e\n\u003cli\u003e1 × Mounting screw set for panel fixing\u003c\/li\u003e\n\u003cli\u003e1 × DIN rail clip set\u003c\/li\u003e\n\u003cli\u003e1 × Product documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eShipping\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWe ship by FedEx, UPS, or DHL based on your delivery needs.\u003c\/li\u003e\n\u003cli\u003eOrders leave the warehouse within 1 to 3 business days.\u003c\/li\u003e\n\u003cli\u003eTracking details reach you by email after carrier pickup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How many racks can I chain on one bus X link?\u003c\/strong\u003e\u003cbr\u003eA: The Modicon Premium platform supports multi-rack layouts through the two SUB-D 9 connectors on each rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does the rack include a power supply?\u003c\/strong\u003e\u003cbr\u003eA: No. You install a TSXPSY power supply in one of the 12 slots.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I mount the TSXRKY12EX vertically?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The DIN rail clips and M6 screws hold the rack in either orientation inside a cabinet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Which processors run in this rack?\u003c\/strong\u003e\u003cbr\u003eA: TSXP57 processors work with the TSXRKY12EX in Modicon Premium systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What cable connects two racks?\u003c\/strong\u003e\u003cbr\u003eA: A SUB-D 9 bus X cable links the female connectors between racks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003e© 2026 Ubest Automation Limited. \u003ca href=\"https:\/\/www.ubestplc.com\/\"\u003ehttps:\/\/www.ubestplc.com\/\u003c\/a\u003e All rights reserved.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eContact: \u003ca href=\"mailto:sales@ubestplc.com\"\u003esales@ubestplc.com\u003c\/a\u003e Phone \u003ca href=\"https:\/\/wa.me\/868618030005825\"\u003e+86 86 180 3000 5825\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":53264791437594,"sku":"TSXRKY12EX","price":257.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/TSXRKY12EX-3.jpg?v=1792659822","url":"https:\/\/www.ubestplc.com\/products\/schneider-tsxrky12ex-12-slot-extendable-rack-get-quote","provider":"Ubest Automation Limited","version":"1.0","type":"link"}