{"product_id":"siemens-6ar1310-0gg40-0aa0-relay-current-monitor","title":"Siemens 6AR1310-0GG40-0AA0 Relay | Current Monitor","description":"\u003ch2\u003eSiemens 6AR1310-0GG40-0AA0 Current Monitoring Relay\u003c\/h2\u003e\n\u003cp\u003eProtect your equipment from current faults. The \u003cstrong\u003eSiemens 6AR1310-0GG40-0AA0\u003c\/strong\u003e is a digital monitoring relay. It watches for over-current and under-current conditions. Works with both AC and DC systems. A vital component for motor and pump monitoring.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eRelay Features \u0026amp; Core Benefits\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDetects dangerous over-current and under-current conditions.\u003c\/li\u003e\n\u003cli\u003eWorks with 24V AC or DC power for easy integration.\u003c\/li\u003e\n\u003cli\u003eDigital design for accurate and stable setpoints.\u003c\/li\u003e\n\u003cli\u003eHelps prevent motor burnout and pump dry-running.\u003c\/li\u003e\n\u003cli\u003eCompact design saves space in your control cabinet.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eComplete Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e Siemens \u003cstrong\u003e6AR1310-0GG40-0AA0\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Digital Monitoring Relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitoring Function:\u003c\/strong\u003e Current (Amps)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetection:\u003c\/strong\u003e Overshoot (Over-Current) \u0026amp; Undershoot (Under-Current)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 24 VAC \/ 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Frequency:\u003c\/strong\u003e 50\/60 Hz (for AC supply)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Input:\u003c\/strong\u003e 0...5 A AC\/DC (via external current transformer)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSetpoint Adjustment:\u003c\/strong\u003e Digital via buttons or software\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Contacts:\u003c\/strong\u003e 2 changeover (SPDT) relay outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Rating:\u003c\/strong\u003e Typically 250VAC, 5A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to +40°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e 0°C to +50°C\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e Up to 80% (non-condensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN Rail (35mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Class:\u003c\/strong\u003e IP20 (for indoor enclosure)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eUse this relay to monitor current and protect critical assets.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMotor overload and underload protection.\u003c\/li\u003e\n\u003cli\u003eMonitoring pump operation (dry-run protection).\u003c\/li\u003e\n\u003cli\u003eConveyor belt slip or blockage detection.\u003c\/li\u003e\n\u003cli\u003eFan and blower monitoring.\u003c\/li\u003e\n\u003cli\u003eGeneral machine load supervision.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eOrdering \u0026amp; Support\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWe ship fast via FedEx, UPS, and DHL. The \u003cstrong\u003eSiemens 6AR1310-0GG40-0AA0\u003c\/strong\u003e relay is new and includes a 12-month product warranty.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I connect a high-current motor to this low-current relay?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou must use an external current transformer (CT). The CT steps down the motor current (e.g., 100A) to a safe, measurable level (e.g., 5A) for the relay's input terminals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between overshoot and undershoot detection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOvershoot trips if current exceeds your high setpoint (overload). Undershoot trips if current falls below your low setpoint (like a broken belt or empty pump).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this relay for three-phase motor monitoring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, but you typically need one current transformer per phase. The relay monitors one phase. For full protection, you may need three relays or a specialized 3-phase monitor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow are the setpoints configured?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eModels like this often have front-panel buttons and a display for setting thresholds and delay times. Refer to the manual for the exact procedure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFrom field experience, what causes false under-current trips?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSetting the under-current threshold too close to the motor's normal running current. Account for normal load variations. Always set the trip point at least 20-30% below the expected minimum running current under normal conditions.\u003c\/p\u003e\n\u003cp\u003e© 2025 Ubest Automation Limited. All rights reserved.\u003cbr\u003eVisit: \u003ca href=\"https:\/\/www.ubestplc.com\/\"\u003ehttps:\/\/www.ubestplc.com\/\u003c\/a\u003e\u003cbr\u003eEmail: \u003ca href=\"mailto:sales@ubestplc.com\"\u003esales@ubestplc.com\u003c\/a\u003e | Call\/WhatsApp: \u003ca href=\"https:\/\/wa.me\/8618030005825\"\u003e+86 180 3000 5825\u003c\/a\u003e\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":51409855807770,"sku":"6AR1310-0GG40-0AA0","price":184.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/6AR1310-0GG40-0AA0_2.jpg?v=1764640081","url":"https:\/\/www.ubestplc.com\/products\/siemens-6ar1310-0gg40-0aa0-relay-current-monitor","provider":"Ubest Automation Limited","version":"1.0","type":"link"}