{"product_id":"siemens-et-200sp-output-module-6es7132-6bf01-0ba0","title":"Siemens ET 200SP Output Module | 6ES7132-6BF01-0BA0","description":"\u003ch2\u003e\u003cstrong\u003eSiemens 6ES7132-6BF01-0BA0: Compact \u0026amp; Intelligent Digital Output Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eEnhance your distributed I\/O system with the Siemens \u003cstrong\u003e6ES7132-6BF01-0BA0\u003c\/strong\u003e digital output module. This ET 200SP module provides eight sourcing (PNP) outputs, each capable of switching 0.5A at 24V DC. It delivers advanced diagnostics and robust performance for demanding automation tasks in a space-saving 15mm width.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features \u0026amp; System Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Density Outputs:\u003c\/strong\u003e Controls eight devices with \u003cstrong style=\"color: #e74c3c;\"\u003e0.5 A per channel and 4 A total module current\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Diagnostics:\u003c\/strong\u003e Detects \u003cstrong style=\"color: #e74c3c;\"\u003ewire-break, short-circuit to L+\/M, and supply voltage faults\u003c\/strong\u003e for each channel group.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSourcing (PNP) Outputs:\u003c\/strong\u003e Supplies 24V to the load, compatible with common PLC sinking inputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeamless Integration:\u003c\/strong\u003e Requires an ET 200SP BaseUnit Type A0 with \u003cstrong style=\"color: #e74c3c;\"\u003eColor Code CC02\u003c\/strong\u003e for correct mounting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Configuration Support:\u003c\/strong\u003e Works with STEP 7 (TIA Portal from V14) and PCS 7.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eComplete Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Family:\u003c\/strong\u003e Siemens SIMATIC ET 200SP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder Number:\u003c\/strong\u003e \u003cstrong\u003e6ES7132-6BF01-0BA0\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Designation:\u003c\/strong\u003e DQ 8x24VDC\/0.5A ST (Standard)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Outputs:\u003c\/strong\u003e 8 channels, sourcing (PNP)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current per Channel:\u003c\/strong\u003e \u003cstrong style=\"color: #e74c3c;\"\u003e0.5 A (max)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Current per Module:\u003c\/strong\u003e \u003cstrong style=\"color: #e74c3c;\"\u003e4 A (max)\u003c\/strong\u003e @ 60°C horizontal mount\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e 24 V DC nominal (19.2 - 28.8 V DC range)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad Type:\u003c\/strong\u003e Resistive, lamp, inductive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching Frequency:\u003c\/strong\u003e Up to 100 Hz (resistive load)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching Delay:\u003c\/strong\u003e Typically 50 µs (0-\u0026gt;1), 100 µs (1-\u0026gt;0)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-Circuit Protection:\u003c\/strong\u003e Yes, electronic, with diagnostic reporting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Functions:\u003c\/strong\u003e Wire-break, Short-circuit (L+\/M), Supply voltage monitoring, Group error.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Indicators:\u003c\/strong\u003e Green PWR LED, Green\/Red DIAG LED, Green per-channel status LED.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Voltage (Electronic):\u003c\/strong\u003e 24 V DC via backplane bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Loss:\u003c\/strong\u003e Typical 1 W.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential Separation:\u003c\/strong\u003e Between channels and backplane bus (707 V DC type test).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBaseUnit Compatibility:\u003c\/strong\u003e \u003cstrong style=\"color: #e74c3c;\"\u003eBU Type A0\u003c\/strong\u003e (mandatory)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoding Element:\u003c\/strong\u003e Type A (mechanical)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient Temperature:\u003c\/strong\u003e -30°C to +60°C (horizontal) \/ -30°C to +50°C (vertical).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (WxHxD):\u003c\/strong\u003e 15 mm x 73 mm x 58 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e Approx. 30 g.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOne (1) Siemens ET 200SP Digital Output Module (6ES7132-6BF01-0BA0).\u003c\/li\u003e\n\u003cli\u003eOne (1) color identification plate (CC02 - blue).\u003c\/li\u003e\n\u003cli\u003eModule is supplied in its original protective Siemens packaging.\u003c\/li\u003e\n\u003cli\u003eNote: BaseUnit (BU) and server module must be ordered separately.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eWarranty Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThis module includes a standard \u003cstrong style=\"color: #e74c3c;\"\u003e12-month warranty\u003c\/strong\u003e from the purchase date.\u003c\/li\u003e\n\u003cli\u003eThe warranty covers any operational defects under normal installation and use.\u003c\/li\u003e\n\u003cli\u003eTechnical support is available to assist with configuration and diagnostics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping \u0026amp; Delivery\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWe ship worldwide using reliable couriers: \u003cstrong style=\"color: #e74c3c;\"\u003eFedEx, UPS, and DHL\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eAll electronic components are packed to prevent electrostatic discharge and physical damage.\u003c\/li\u003e\n\u003cli\u003eYou will receive a tracking number via email as soon as the shipment is dispatched.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePractical Application FAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I connect this module to control a relay coil or a small solenoid valve directly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the 0.5A per channel rating is ideal for directly driving standard 24V DC relay coils, pilot lights, or small solenoid valves. Always check the inrush current of inductive loads; it must not exceed the module's short-circuit response threshold.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between \"sourcing\" (PNP) and \"sinking\" (NPN) outputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis \u003cstrong\u003e6ES7132-6BF01-0BA0\u003c\/strong\u003e module is sourcing (PNP). It switches the positive voltage (24V) to the load. The load's other side connects to 0V (M). A sinking (NPN) output switches the 0V side to the load.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the wire-break diagnostics work on this digital output module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module monitors a tiny current flow when the output is switched ON. If the circuit is open (wire break), this current drops to zero, and the module sets a diagnostic bit. Note: Diagnostics typically work per group of 4 or 8 channels, not per individual channel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I parallel two outputs to drive a single load requiring more than 0.5A?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe manual states \"for uprating: No.\" Paralleling outputs to increase current is not supported and risks damaging the module. For loads \u0026gt;0.5A, use an external interposing relay or a different module with a higher current rating.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens to the outputs if the module loses communication with the PLC?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou can configure a \"substitute value\" behavior for each channel or group in the hardware configuration. You can set outputs to switch to a defined safe state (0 or 1) or retain the last value when a communication fault occurs.\u003c\/p\u003e\n\u003cp\u003e© 2025 Ubest Automation Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.ubestplc.com\/\"\u003ehttps:\/\/www.ubestplc.com\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@ubestplc.com\"\u003esales@ubestplc.com\u003c\/a\u003e | Phone: \u003ca href=\"https:\/\/wa.me\/8618030005825\"\u003e+86 180 3000 5825\u003c\/a\u003e\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":51409699602714,"sku":"6ES7132-6BF01-0BA0","price":182.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/6ES7132-6BF01-0BA0.jpg?v=1764640081","url":"https:\/\/www.ubestplc.com\/products\/siemens-et-200sp-output-module-6es7132-6bf01-0ba0","provider":"Ubest Automation Limited","version":"1.0","type":"link"}