{"product_id":"tm200c40r-schneider-m200-relay-controller-request-quote","title":"TM200C40R Schneider M200 Relay Controller – Request Quote","description":"\u003ch2\u003e\u003cstrong\u003eTM200C40R Schneider Electric Logic Controller – 40 I\/O Relay Controller for Demanding Automation\u003c\/strong\u003e\u003c\/h2\u003e\u003cp\u003eThe \u003cstrong\u003eTM200C40R\u003c\/strong\u003e from Schneider Electric belongs to the Easy Modicon M200 range. This logic controller delivers 40 discrete I\/O points with 16 relay outputs. Engineers choose the \u003cstrong\u003eTM200C40R\u003c\/strong\u003e for flexible machine control and reliable relay switching. The design suits panel builders who need fast inputs and robust relay outputs in one compact unit.\u003c\/p\u003e\u003ch3\u003e\u003cstrong\u003eSummary\u003c\/strong\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eThe \u003cstrong\u003eTM200C40R\u003c\/strong\u003e combines 24 discrete inputs with 16 relay outputs in a single controller.\u003c\/li\u003e \u003cli\u003eFour high-speed inputs reach 100 kHz for counting and positioning tasks.\u003c\/li\u003e \u003cli\u003eThe 100–240 V AC supply suits industrial cabinets without a separate DC bus.\u003c\/li\u003e \u003cli\u003eFour expansion modules extend the system to 128 transistor outputs or 80 relay outputs.\u003c\/li\u003e \u003cli\u003eDual serial links and a USB port simplify programming and field communication.\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Schneider Electric\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eTM200C40R\u003c\/strong\u003e\n\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eRange:\u003c\/strong\u003e Easy Modicon M200\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Logic controller\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eRated supply voltage:\u003c\/strong\u003e 100…240 V AC, 50\/60 Hz\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSupply voltage limits:\u003c\/strong\u003e 85…264 V\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eInrush current:\u003c\/strong\u003e 50 A\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003ePower consumption:\u003c\/strong\u003e 59…69 VA at full I\/O load\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eDiscrete I\/O number:\u003c\/strong\u003e 40 total (24 inputs, 16 relay outputs)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eDiscrete input voltage:\u003c\/strong\u003e 24 V DC, sink or source type 1 per EN\/IEC 61131-2\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eDiscrete input current:\u003c\/strong\u003e 7 mA per input\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eInput impedance:\u003c\/strong\u003e 3.3 kOhm\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eLogic thresholds:\u003c\/strong\u003e State 1 ≥ 15 V; State 0 ≤ 5 V\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eFast inputs:\u003c\/strong\u003e I2…I5 with 35 µs turn-on and 100 µs turn-off\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eHigh-speed inputs:\u003c\/strong\u003e I0, I1, I6, I7 with 5 µs response\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eRegular inputs:\u003c\/strong\u003e I8…I23 with configurable filtering of 0\/3\/12 ms\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eRelay output type:\u003c\/strong\u003e Normally open, 2 A per output\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eOutput voltage limits:\u003c\/strong\u003e 30 V DC \/ 250 V AC\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMaximum current per common:\u003c\/strong\u003e 4 A at COM 0, COM 1, COM 2, COM 3\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eRelay response time:\u003c\/strong\u003e 10 ms turn-on and 10 ms turn-off\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eElectrical durability:\u003c\/strong\u003e 100,000 cycles at AC-12 240 V \/ 480 VA resistive\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMechanical durability:\u003c\/strong\u003e 20,000,000 cycles\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMinimum load:\u003c\/strong\u003e 10 mA at 5 V DC\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSwitching frequency:\u003c\/strong\u003e 0.1 Hz at maximum load\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMemory:\u003c\/strong\u003e 512 byte internal flash for program backup\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eData storage:\u003c\/strong\u003e 32 GB micro SD card (optional)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eBattery:\u003c\/strong\u003e BR2032 Li-CFx, 5-year life, 3-year backup at 25 °C\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eExecution time:\u003c\/strong\u003e 0.2 µs per Boolean instruction; 0.3 ms per 1 K instructions\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEvent task response:\u003c\/strong\u003e 60 µs\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eClock drift:\u003c\/strong\u003e ≤ 90 s\/month at 25 °C\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003ePID regulation:\u003c\/strong\u003e Up to 14 simultaneous loops\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eCounting inputs:\u003c\/strong\u003e 4 HSC channels at 100 kHz, 32 bits\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eHSC modes:\u003c\/strong\u003e Quadrature x1\/x2\/x4, Pulse\/Direction, Single phase, CW\/CCW\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eCommunication and Programming Interfaces\u003c\/strong\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eUSB mini B 2.0 port supports the SoMachine-Network protocol for programming.\u003c\/li\u003e \u003cli\u003eSerial link 1 provides an RS485 interface on a removable terminal block.\u003c\/li\u003e \u003cli\u003eSerial link 2 offers RS232\/RS485 or isolated RS485 options.\u003c\/li\u003e \u003cli\u003eBaud rates range from 1.2 to 115.2 kbit\/s; RS485 reaches 15 m and RS232 reaches 3 m.\u003c\/li\u003e \u003cli\u003eSerial ports run Modbus master\/slave RTU\/ASCII or SoMachine-Network.\u003c\/li\u003e \u003cli\u003eSeven status LEDs cover PWR, RUN, ERR, SD, BAT, SL1, and per-channel I\/O state.\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eEnvironmental Immunity and Operating Limits\u003c\/strong\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eOperating temperature ranges from \u003cspan style=\"color:#c0392b;\"\u003e\u003cstrong\u003e0…55 °C\u003c\/strong\u003e\u003c\/span\u003e for horizontal installation.\u003c\/li\u003e \u003cli\u003eStorage temperature ranges from \u003cspan style=\"color:#c0392b;\"\u003e\u003cstrong\u003e-25…70 °C\u003c\/strong\u003e\u003c\/span\u003e.\u003c\/li\u003e \u003cli\u003eRelative humidity stays at 10…95 % without condensation.\u003c\/li\u003e \u003cli\u003eElectrostatic discharge immunity reaches 8 kV air and 6 kV contact per EN\/IEC 61000-4-2.\u003c\/li\u003e \u003cli\u003eRadiated field immunity reaches 10 V\/m from 80 MHz to 3 GHz per EN\/IEC 61000-4-3.\u003c\/li\u003e \u003cli\u003eFast transient immunity reaches 2 kV on power lines and relay outputs per EN\/IEC 61000-4-4.\u003c\/li\u003e \u003cli\u003eSurge immunity reaches 2 kV on AC power lines and relay outputs per EN\/IEC 61000-4-5.\u003c\/li\u003e \u003cli\u003eConducted RF immunity reaches 10 V from 0.15 to 80 MHz per EN\/IEC 61000-4-6.\u003c\/li\u003e \u003cli\u003eShock resistance reaches 15 gn for 11 ms and 30 gn for 6 ms.\u003c\/li\u003e \u003cli\u003eVibration resistance reaches 3.5 mm at 5…8.4 Hz and 1 gn at 8.4…150 Hz on rail.\u003c\/li\u003e \u003cli\u003ePollution degree stays at 2 or lower; operating altitude reaches 2000 m.\u003c\/li\u003e \u003cli\u003eProtection degree is IP20 with the cover in place.\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eMechanical Data and Mounting Guide\u003c\/strong\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eDimensions measure 175 mm wide, 90 mm high, and 70 mm deep.\u003c\/li\u003e \u003cli\u003eNet weight is 0.504 kg.\u003c\/li\u003e \u003cli\u003eMount the unit on a TH35-15 top hat rail per IEC 60715.\u003c\/li\u003e \u003cli\u003eAlternatively use a TH35-7.5 plate or panel with the fixing kit.\u003c\/li\u003e \u003cli\u003eKeep unshielded input cable runs below 50 m.\u003c\/li\u003e \u003cli\u003eKeep shielded fast and high-speed input cables below 10 m.\u003c\/li\u003e \u003cli\u003eKeep unshielded output cable runs below 150 m.\u003c\/li\u003e \u003cli\u003eWire inputs and outputs to removable screw terminal blocks.\u003c\/li\u003e \u003cli\u003eFeed 100–240 V AC power through the 3-terminal removable block.\u003c\/li\u003e \u003cli\u003eThe controller supplies 24 V DC at 300 mA to external sensors.\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e1 × Schneider Electric \u003cstrong\u003eTM200C40R\u003c\/strong\u003e logic controller\u003c\/li\u003e \u003cli\u003eRemovable screw terminal blocks for inputs, outputs, serial link, and power\u003c\/li\u003e \u003cli\u003eProduct documentation set\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eShipping and Delivery\u003c\/strong\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eWe ship worldwide by FedEx, UPS, and DHL.\u003c\/li\u003e \u003cli\u003eOrders leave the warehouse within 1–3 business days after payment clears.\u003c\/li\u003e \u003cli\u003eTracking numbers reach your inbox as soon as the carrier scans the parcel.\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eQ: How many relay outputs does the TM200C40R provide?\u003c\/strong\u003e\u003cbr\u003eA: It provides 16 normally open relay outputs rated at 2 A each.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eQ: Can I expand the I\/O count?\u003c\/strong\u003e\u003cbr\u003eA: Yes, you can add up to 4 expansion modules for 80 relay outputs or 128 transistor outputs.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eQ: Which software programs this controller?\u003c\/strong\u003e\u003cbr\u003eA: SoMachine software connects through the USB mini B port or a serial link.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eQ: Does the controller support high-speed counting?\u003c\/strong\u003e\u003cbr\u003eA: Yes, four HSC inputs run at 100 kHz with 32-bit resolution.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eQ: What supply voltage does the unit accept?\u003c\/strong\u003e\u003cbr\u003eA: It accepts 100…240 V AC at 50\/60 Hz with limits of 85…264 V.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eQ: How many PID loops can run at once?\u003c\/strong\u003e\u003cbr\u003eA: The controller handles up to 14 simultaneous PID loops.\u003c\/li\u003e \u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003e© 2026 Ubest Automation Limited. \u003ca href=\"https:\/\/www.ubestplc.com\/\"\u003ehttps:\/\/www.ubestplc.com\/\u003c\/a\u003e All rights reserved.\u003c\/strong\u003e\u003cbr\u003e Contact: \u003ca href=\"mailto:sales@ubestplc.com\"\u003esales@ubestplc.com\u003c\/a\u003e | \u003ca href=\"https:\/\/wa.me\/868618030005825\"\u003e+86 86 180 3000 5825\u003c\/a\u003e\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":53160585429274,"sku":"TM200C40R","price":257.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/TM200C40R.jpg?v=1792659455","url":"https:\/\/www.ubestplc.com\/products\/tm200c40r-schneider-m200-relay-controller-request-quote","provider":"Ubest Automation Limited","version":"1.0","type":"link"}