{"product_id":"tm218lda24drn-schneider-modicon-m218-plc-request-quote","title":"TM218LDA24DRN Schneider Modicon M218 PLC - Request Quote","description":"\u003ch2\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eSchneider Electric designed the \u003cstrong\u003eTM218LDA24DRN\u003c\/strong\u003e logic controller to streamline automated machine control across industrial environments. This robust Modicon M218 series unit provides reliable execution for small to medium automation projects. Engineers choose the \u003cstrong\u003eTM218LDA24DRN\u003c\/strong\u003e controller because it delivers flexible digital control in a compact frame.\u003c\/p\u003e\n\n\u003ch2\u003e\u003cstrong\u003eProduct Summary and Pyramid Framework\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eThe apex of our product structure highlights high automation efficiency through compact logic control architecture.\u003c\/li\u003e\n  \u003cli\u003eThe middle framework level organizes functional capabilities, hardware specifications, and complex system wiring requirements logically.\u003c\/li\u003e\n  \u003cli\u003eThe foundation level details field installation procedures, packaging options, and reliable fast shipping logistics methods.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eModel Nomenclature Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eThe prefix code TM218 clearly identifies the compact Schneider Electric Modicon M218 programmable controller family.\n    \u003cul\u003e\n      \u003cli\u003eThe letter L represents the streamlined compact logic controller framework without internal expansion chassis components.\u003c\/li\u003e\n      \u003cli\u003eThe code DA indicates direct digital input and output connection capabilities for discrete field devices.\u003c\/li\u003e\n      \u003cli\u003eThe number 24 specifies twenty-four total active digital channels on the primary controller terminal block.\u003c\/li\u003e\n      \u003cli\u003eThe letter D designates direct current operational electrical power for incoming field sensor signals.\u003c\/li\u003e\n      \u003cli\u003eThe designation R confirms electromagnetic relay contact outputs for switching heavier industrial external loads.\u003c\/li\u003e\n      \u003cli\u003eThe suffix N marks the standard non-isolated removable screw terminal block connection interface layout.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003e\u003cstrong\u003eTechnical Parameters\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eManufacturer Schneider Electric produces the high-quality \u003cspan style=\"color: #0056b3;\"\u003eModicon M218\u003c\/span\u003e programmable logic controller platform for global industry.\u003c\/li\u003e\n  \u003cli\u003eThe official product model \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eTM218LDA24DRN\u003c\/strong\u003e\u003c\/span\u003e handles complex local plant automation sequences without continuous human supervision.\u003c\/li\u003e\n  \u003cli\u003eThe main hardware unit integrates \u003cspan style=\"color: #d9534f;\"\u003etwelve regular digital inputs\u003c\/span\u003e alongside two fast high-speed counter channels.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cspan style=\"color: #d9534f;\"\u003eTen robust relay outputs\u003c\/span\u003e directly control external actuators while maintaining reliable galvanic electrical isolation protection.\u003c\/li\u003e\n  \u003cli\u003eStandard digital inputs draw \u003cspan style=\"color: #0056b3;\"\u003efive milliamperes\u003c\/span\u003e while enhanced fast inputs demand seven milliamperes electric current.\u003c\/li\u003e\n  \u003cli\u003eFlexible sink and source circuitry accepts an operational voltage range from zero to twenty-eight point eight volts.\u003c\/li\u003e\n  \u003cli\u003eHigh-speed digital input channels achieve a maximum pulse frequency response of \u003cspan style=\"color: #2e7d32;\"\u003eten kilohertz\u003c\/span\u003e during operation.\u003c\/li\u003e\n  \u003cli\u003eThe digital input stage lacks built-in overvoltage protection and requires external surge suppression protection units.\u003c\/li\u003e\n  \u003cli\u003eOperating ambient temperatures range from minus ten to plus fifty-five degrees Celsius without performance degradation.\u003c\/li\u003e\n  \u003cli\u003eHeavy industrial metal shielding protects all internal microprocessor components against severe external electromagnetic interference noise.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEngineers mount the compact unit onto standard thirty-five millimeter DIN rails inside enclosed metal cabinets.\u003c\/li\u003e\n  \u003cli\u003eTechnicians must secure reliable ground wires before connecting primary direct current electrical power source lines.\u003c\/li\u003e\n  \u003cli\u003eMaintenance teams position field wiring cables away from heavy power transformers to prevent signal degradation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003e\u003cstrong\u003ePacking List and Shipping Logistics\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eThe factory box contains one primary controller unit sealed inside an anti-static protective plastic bag.\u003c\/li\u003e\n  \u003cli\u003eRemovable screw terminal blocks sit securely attached to the main logic controller wiring connection ports.\u003c\/li\u003e\n  \u003cli\u003eWe dispatch all ordered automation products globally through trusted express carriers FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eDoes the primary controller unit require external surge suppression hardware during standard industrial field installation?\u003c\/li\u003e\n  \u003cli\u003eYes, users must add external surge suppressors because the inputs lack built-in overvoltage protection circuits.\u003c\/li\u003e\n  \u003cli\u003eHow many total digital input channels does this compact logic controller unit currently offer users?\u003c\/li\u003e\n  \u003cli\u003eThe unit offers fourteen total digital inputs including twelve regular channels and two high-speed counters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\u003cstrong\u003e© 2026 Ubest Automation Limited. \u003ca href=\"https:\/\/www.ubestplc.com\/\"\u003ehttps:\/\/www.ubestplc.com\/\u003c\/a\u003e All rights reserved.\u003c\/strong\u003e\u003c\/li\u003e\n  \u003cli\u003eContact: Email \u003ca href=\"mailto:sales@ubestplc.com\"\u003esales@ubestplc.com\u003c\/a\u003e Phone \u003ca href=\"https:\/\/wa.me\/8618030005825\"\u003e+86 86 180 3000 5825\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":52716386877722,"sku":"TM218LDA24DRN","price":163.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/TM218LDA24DRN.jpg?v=1787128428","url":"https:\/\/www.ubestplc.com\/products\/tm218lda24drn-schneider-modicon-m218-plc-request-quote","provider":"Ubest Automation Limited","version":"1.0","type":"link"}