{"product_id":"tsxpby100-schneider-electric-profibus-dp-module","title":"TSXPBY100 Schneider Electric Profibus-DP Module","description":"\u003ch2\u003eSchneider Electric Modicon TSXPBY100 Profibus-DP Master Module\u003c\/h2\u003e\n\u003cp\u003eThe Schneider Electric \u003cstrong\u003eTSXPBY100\u003c\/strong\u003e is a Profibus-DP communication module for Modicon Premium PLC systems. This module enables high-speed industrial network connectivity as a Class 1 and Class 2 master. It comes as a complete kit with a PCMCIA card and connection accessories. The \u003cstrong\u003eTSXPBY100\u003c\/strong\u003e provides robust data exchange with a large number of field devices.\u003c\/p\u003e\n\u003ch3\u003eCore Module Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #d35400;\"\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e Schneider Electric\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #d35400;\"\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e TSXPBY100\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Line:\u003c\/strong\u003e Modicon TSX Micro \/ Premium Automation Platform\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Type:\u003c\/strong\u003e Profibus-DP V0 Master Option Module Kit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible PLCs:\u003c\/strong\u003e Modicon Premium, Atrium Slot-PLC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Interface:\u003c\/strong\u003e RS-485\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransmission Rates:\u003c\/strong\u003e 9.6 Kbit\/s to 12 Mbit\/s (Auto-negotiating)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaster Class:\u003c\/strong\u003e Class 1 (Cyclic Data) and Class 2 (Configuration\/Diagnostics)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransmission Mode:\u003c\/strong\u003e NRZ (Non-Return to Zero)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Type:\u003c\/strong\u003e Twisted, Shielded Pair\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Format:\u003c\/strong\u003e Standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKit Net Weight:\u003c\/strong\u003e 0.87 kg (1.92 lb)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNetwork Performance \u0026amp; Capacity\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Number of Slaves:\u003c\/strong\u003e 126 Devices (with addressing 0-125)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Data Capacity:\u003c\/strong\u003e 3872 Input Bytes \/ 3872 Output Bytes (per scan)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSegment Length (12 Mbit\/s):\u003c\/strong\u003e 100 m (328 ft) without repeater\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSegment Length (12 Mbit\/s):\u003c\/strong\u003e 400 m (1312 ft) with 3 repeaters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSegment Length (9.6 Kbit\/s):\u003c\/strong\u003e 1200 m (3937 ft) without repeater\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSegment Length (9.6 Kbit\/s):\u003c\/strong\u003e 4800 m (15748 ft) with 3 repeaters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommunication Services \u0026amp; Functions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClass 1 Master Services:\u003c\/strong\u003e Read\/Write DP Slave I\/O Data, Set Slave Parameters (on power-up), Transfer Slave Diagnostic Data, Check Slave Configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClass 2 Master Services:\u003c\/strong\u003e Manage Monitoring Requests (Global CONTROL, Get Master Diag)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNot Supported:\u003c\/strong\u003e Profibus FMS Message Handling, Master-to-Master Dialogue\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Done via the PLC programming software (Unity Pro\/PL7)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKit Contents \u0026amp; Physical Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHost Module:\u003c\/strong\u003e Plugs into the PLC's option slot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePCMCIA Communication Card:\u003c\/strong\u003e Contains the Profibus firmware and processor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Connecting Cable:\u003c\/strong\u003e 0.6 m length for card-to-module connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eT-Junction Box:\u003c\/strong\u003e Enables a tap link to the main Profibus trunk cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e 400 mA @ 5V DC (supplied from the PLC rack).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Connection:\u003c\/strong\u003e 9-pin D-Sub connector (female) for Profibus network.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental \u0026amp; Durability Ratings\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to +60°C (32°F to 140°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -25°C to +70°C (-13°F to 158°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e 5% to 95% RH (non-condensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Altitude:\u003c\/strong\u003e 0 to 2000 meters (0 to 6561 ft)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration Immunity:\u003c\/strong\u003e Complies with IEC 60068-2-6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock Immunity:\u003c\/strong\u003e Complies with IEC 60068-2-27\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Immunity:\u003c\/strong\u003e Complies with IEC 61000-4-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Network Setup\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInsert the PCMCIA card firmly into the host module.\u003c\/li\u003e\n\u003cli\u003eInstall the host module into an available option slot on the Premium PLC rack.\u003c\/li\u003e\n\u003cli\u003eConnect the integrated 0.6m cable between the card and the module.\u003c\/li\u003e\n\u003cli\u003eWire the Profibus trunk cable to the module's 9-pin D-Sub connector.\u003c\/li\u003e\n\u003cli\u003eUse the provided T-junction box for convenient spur connections if needed.\u003c\/li\u003e\n\u003cli\u003eSet unique addresses (1-125) for all slave devices on the network.\u003c\/li\u003e\n\u003cli\u003eConfigure the network parameters (baud rate, I\/O mapping) in Unity Pro software.\u003c\/li\u003e\n\u003cli\u003eTerminate both ends of the Profibus trunk cable with the included or external 220Ω resistors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackaging \u0026amp; Shipping Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Contents:\u003c\/strong\u003e 1 x Host Module, 1 x PCMCIA Card, 1 x 0.6m Cable, 1 x T-Junction Box, Documentation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Dimensions (L x W x H):\u003c\/strong\u003e 27.5 x 24.5 x 24.5 cm (10.8 x 9.6 x 9.6 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Gross Weight:\u003c\/strong\u003e 1.309 kg (2.886 lb)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping GTIN (EAN):\u003c\/strong\u003e 3389110105438\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Methods:\u003c\/strong\u003e FedEx, UPS, DHL Express services available.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e France (FR)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReturn Policy:\u003c\/strong\u003e This communication module kit is non-returnable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty \u0026amp; Support\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Period:\u003c\/strong\u003e 12 months from the date of purchase.\u003c\/li\u003e\n\u003cli\u003eWarranty covers defects in materials and manufacturing.\u003c\/li\u003e\n\u003cli\u003eNetwork configuration support is available for complex slave device integration.\u003c\/li\u003e\n\u003cli\u003eAlways use certified Profibus connectors and cable for reliable network operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat is the difference between Class 1 and Class 2 master functionality?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eClass 1 master handles the cyclic, real-time exchange of input\/output data with slaves. Class 2 master is used for non-cyclic services like parameterization, configuration, and detailed diagnostics, often accessed from an engineering tool.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCan I connect this to a Siemens Profibus network?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eYes, Profibus-DP is a vendor-independent standard. The TSXPBY100 can act as a master for any standard Profibus-DP slave device, including those from Siemens, SEW, Festo, and many others.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhy does the network length depend on the transmission rate?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHigher data rates are more susceptible to signal degradation over distance. At 12 Mbit\/s, capacitance and attenuation limit the reliable cable length to 100m. At slower rates like 9.6 Kbit\/s, the signal can travel much farther (1200m) without degradation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eHow do I configure the I\/O mapping for the slaves?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIn Unity Pro, you import the GSD (device description) file for each slave device type. The software then lets you assign the slave's I\/O data to specific %I and %Q memory addresses in the PLC, creating a hardware configuration.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat happens if the PCMCIA card is removed while the PLC is powered?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRemoving the card during operation will cause a communication fault. The PLC will likely flag an I\/O error on the Profibus module, and all data exchange with the slave devices will stop until the card is reinserted and the fault is cleared.\u003c\/p\u003e\n\u003cp\u003e© 2026 Ubest Automation Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.ubestplc.com\/\"\u003ehttps:\/\/www.ubestplc.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@ubestplc.com\"\u003esales@ubestplc.com\u003c\/a\u003e Phone: \u003ca href=\"https:\/\/wa.me\/8618030005825\"\u003e+86 180 3000 5825\u003c\/a\u003e\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":51469225328922,"sku":"TSXPBY100","price":205.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/TSXPBY100-1.jpg?v=1790047251","url":"https:\/\/www.ubestplc.com\/products\/tsxpby100-schneider-electric-profibus-dp-module","provider":"Ubest Automation Limited","version":"1.0","type":"link"}