{"product_id":"xnx-amav-nnic1-honeywell-xnx-gas-detector-ir-co2-transmitter","title":"XNX-AMAV-NNIC1 Honeywell XNX Gas Detector IR CO2 Transmitter","description":"\u003ch3\u003e\u003cstrong\u003eHoneywell XNX-AMAV-NNIC1 Universal Gas Transmitter\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell XNX-AMAV-NNIC1\u003c\/strong\u003e universal transmitter delivers high-performance infrared gas detection for demanding industrial environments. This model combines a rugged painted aluminum housing with an advanced \u003cstrong\u003eMPD IR Carbon Dioxide sensor\u003c\/strong\u003e to monitor \u003cspan style=\"color: #d9534f;\"\u003e\u003cstrong\u003eCO2 levels from 0 to 5% Vol\u003c\/strong\u003e\u003c\/span\u003e. Featuring \u003cstrong\u003eHART over 4-20mA\u003c\/strong\u003e communication, the unit integrates smoothly into legacy control systems and modern distributed automation platforms.\u003c\/p\u003e\n\u003cp\u003eDesigned for multi-hazard environments, the \u003cstrong\u003eXNX\u003c\/strong\u003e series supports flame, toxic, and combustible gas monitoring across offshore platforms, chemical plants, and manufacturing facilities. The modular architecture lowers long-term maintenance overhead, simplifies field wiring, and ensures rapid sensor replacement under harsh operational conditions.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eHoneywell\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #d9534f;\"\u003e\u003cstrong\u003eXNX-AMAV-NNIC1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #d9534f;\"\u003e\u003cstrong\u003eXNX Universal Transmitter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 5% Vol IR Carbon Dioxide (CO2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMulti-Purpose Detector (MPD) Infrared Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHART over 4-20mA Analog Signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eT90 less than 30 seconds for fast gas detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity \u0026amp; Linearity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh optical accuracy with non-linear compensation curves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01% Vol CO2 digital resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to +65°C operational limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP66 rated marine-grade painted aluminum enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterference Immunity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdvanced optical filtering resists humidity, dust, and poison gases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Entries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 x M25 threaded entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHazardous Area Approvals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATEX, IECEx, and INMETRO certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Integration \u0026amp; Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrates directly into \u003cstrong\u003eHoneywell Experion PKS\u003c\/strong\u003e and legacy DCS systems.\u003c\/li\u003e\n\u003cli\u003eSupports standard \u003cstrong\u003e4-20mA HART\u003c\/strong\u003e analog inputs on standard PLC racks.\u003c\/li\u003e\n\u003cli\u003eCommunicates seamlessly with \u003cstrong\u003eSchneider Electric Modicon\u003c\/strong\u003e and \u003cstrong\u003eAllen-Bradley ControlLogix\u003c\/strong\u003e safety modules.\u003c\/li\u003e\n\u003cli\u003eAccepts optional relay or Modbus communication boards for local alarm triggering.\u003c\/li\u003e\n\u003cli\u003eMatches standard industrial mounting brackets for simple wall or pipe mounting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation, Maintenance \u0026amp; Diagnostics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the transmitter with cable entries pointing downward to prevent liquid pooling.\u003c\/li\u003e\n\u003cli\u003eUse M25 explosion-proof cable glands to preserve enclosure ingress protection.\u003c\/li\u003e\n\u003cli\u003ePerform magnetic wand navigation through the toughened glass window safely.\u003c\/li\u003e\n\u003cli\u003eUtilize full HART electronic device descriptions (EDD) for remote diagnostic monitoring.\u003c\/li\u003e\n\u003cli\u003eAccess real-time optical health indicators, fault histories, and calibration logs instantly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCertifications \u0026amp; Standards Compliance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX \/ IECEx Certification:\u003c\/strong\u003e Approved for Zone 1 and Zone 2 explosive gas atmospheres.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eINMETRO Compliance:\u003c\/strong\u003e Certified for industrial safety standards across South American regions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e Independently tested and rated to IP66 standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Safety:\u003c\/strong\u003e Meets global CE mark and EMC immunity guidelines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Industry Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOil \u0026amp; Gas Refining:\u003c\/strong\u003e Monitors CO2 accumulation near flare stacks, processing units, and storage bays.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOffshore Platforms:\u003c\/strong\u003e Resists aggressive salt air while tracking process gas leaks continuously.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChemical Processing:\u003c\/strong\u003e Ensures personnel safety near high-pressure reaction vessels and transfer lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Generation:\u003c\/strong\u003e Inspects generator cooling systems and combustion byproduct channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFood \u0026amp; Beverage Processing:\u003c\/strong\u003e Monitors large-scale carbonation facilities, breweries, and cold storage units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCommercial Details \u0026amp; Packaging List\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Contents:\u003c\/strong\u003e 1 x \u003cstrong\u003eHoneywell XNX-AMAV-NNIC1\u003c\/strong\u003e Transmitter Unit, 1 x MPD IR CO2 Sensor Cartridge, 1 x Magnetic Calibration Tool, Operating Manual.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Protection:\u003c\/strong\u003e Standard 12-month factory warranty against manufacturing defects.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch Lead Time:\u003c\/strong\u003e Fast dispatch within 24-48 hours from order confirmation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Express Partners:\u003c\/strong\u003e Express global delivery via FedEx, UPS, and DHL courier services.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eBuying Guide \u0026amp; Selection Strategy\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify Personality Card:\u003c\/strong\u003e Ensure the 'V' designation (milli-Volt interface) matches your MPD IR sensor requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelect Entry Thread Type:\u003c\/strong\u003e Match the 'M' suffix for metric M25 wiring conduits before ordering.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm Target Gas Target:\u003c\/strong\u003e Verify 0-5% Vol CO2 range covers your specific safety threshold settings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing Material Choice:\u003c\/strong\u003e Choose aluminum for standard industrial use or stainless steel for highly corrosive marine zones.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: Can I calibrate the Honeywell XNX-AMAV-NNIC1 without opening the enclosure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: Yes, you can perform full zero and span calibrations using the external magnetic wand through the glass window without opening the unit or declassifying the zone.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: What cable type should I use for wiring the 4-20mA HART loop?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: We recommend using twisted, individually shielded 2-core or 3-core copper wire (16 to 18 AWG) to ensure stable communication and noise immunity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: How often should the MPD IR CO2 sensor cartridge be bump-tested?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: Field experience suggests conducting a bump test every 6 months under standard conditions, though high-dust or high-vibration sites may benefit from quarterly checks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: What is the main advantage of an optical IR sensor over a standard catalytic bead sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: Infrared sensors do not require oxygen to operate, cannot be poisoned by silicones or sulfides, and maintain excellent zero stability over extended periods.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52736082379034,"sku":"XNX-AMAV-NNIC1","price":158.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/XNX-AMSE-NHNNN.jpg?v=1787554367","url":"https:\/\/www.ubestplc.com\/products\/xnx-amav-nnic1-honeywell-xnx-gas-detector-ir-co2-transmitter","provider":"Ubest Automation Limited","version":"1.0","type":"link"}