{"product_id":"ge-exciter-regulator-static-converter-is200erscg1aaa","title":"GE Exciter Regulator Static Converter | IS200ERSCG1AAA","description":"\u003ch2\u003eGeneral Electric IS200ERSCG1AAA Exciter Regulator Static Converter\u003c\/h2\u003e\n\u003cp\u003eThe General Electric \u003cstrong\u003eIS200ERSCG1AAA\u003c\/strong\u003e delivers robust power conversion for critical excitation control systems. This advanced static converter provides precise PWM DC output for generator excitation applications in power generation facilities.\u003c\/p\u003e\n\u003ch3\u003eProduct Identification \u0026amp; Core Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eManufacturer \u0026amp; Brand\u003c\/span\u003e: General Electric Industrial Systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eModel Number\u003c\/span\u003e: \u003cstrong\u003eIS200ERSCG1AAA\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eProduct Series\u003c\/span\u003e: EX2100 Excitation Controller\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eProduct Type\u003c\/span\u003e: Exciter Regulator Static Converter\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eCountry of Origin\u003c\/span\u003e: United States of America\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eSystem Compatibility\u003c\/span\u003e: Simplex configuration applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Performance \u0026amp; Power Ratings\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eContinuous Output\u003c\/span\u003e: 250V DC at 35A continuous operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003ePeak Output Capacity\u003c\/span\u003e: 250V DC at 52.5A for 10 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eInput Power Sources\u003c\/span\u003e: Rectified AC or station battery DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003ePower Conversion\u003c\/span\u003e: DC\/DC static power conversion\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eSwitching Technology\u003c\/span\u003e: Pulse Width Modulation (PWM)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eEfficiency Rating\u003c\/span\u003e: \u0026gt;95% power conversion efficiency\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePower Semiconductor Configuration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eIGBT Modules\u003c\/span\u003e: Six insulated gate bipolar transistors\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eGate Connections\u003c\/span\u003e: Twelve soldered gate lead points\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003ePower Connections\u003c\/span\u003e: Four bolted power terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eHeat Management\u003c\/span\u003e: Vertical mounting on dedicated heat sink\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eMounting Hardware\u003c\/span\u003e: Four mounting screws for secure attachment\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eThermal Performance\u003c\/span\u003e: Optimized heat dissipation design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSystem Integration \u0026amp; Interface Capabilities\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eBoard Interfacing\u003c\/span\u003e: Connects with ERRR and ERDD boards\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eVoltage Sensing\u003c\/span\u003e: Integrated voltage attenuator circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eField Discharge\u003c\/span\u003e: Dynamic field discharge capability\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eControl Signaling\u003c\/span\u003e: Differential voltage feedback system\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eRelay Function\u003c\/span\u003e: K3 relay for DC link charging bypass\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eCommunication\u003c\/span\u003e: Direct interface with excitation control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Specifications \u0026amp; Dimensions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eBoard Dimensions\u003c\/span\u003e: 4 inches wide × 6 inches high\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eUnit Weight\u003c\/span\u003e: 8 ounces compact design\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eShipping Dimensions\u003c\/span\u003e: 18×12×12 inches protective packaging\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eMounting Style\u003c\/span\u003e: EX2100 rack compatible design\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eForm Factor\u003c\/span\u003e: Standard industrial board layout\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eConstruction\u003c\/span\u003e: Industrial-grade materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Operating Conditions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eOperating Temperature\u003c\/span\u003e: -20°C to +70°C industrial range\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eStorage Temperature\u003c\/span\u003e: -40°C to +85°C safe storage\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eHumidity Range\u003c\/span\u003e: 5% to 95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eVibration Resistance\u003c\/span\u003e: 2G operational vibration\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eAltitude Rating\u003c\/span\u003e: Up to 2000 meters operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eEMC Compliance\u003c\/span\u003e: Industrial electromagnetic compatibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify proper DC link capacitor discharge before installation\u003c\/li\u003e\n\u003cli\u003eFollow specified torque values for bolted connections\u003c\/li\u003e\n\u003cli\u003eEnsure adequate clearance for heat sink ventilation\u003c\/li\u003e\n\u003cli\u003eCheck all solder connections for integrity and quality\u003c\/li\u003e\n\u003cli\u003eConfirm proper grounding and electrical isolation\u003c\/li\u003e\n\u003cli\u003eValidate interface connections with ERRR and ERDD boards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Documentation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOne IS200ERSCG1AAA static converter unit\u003c\/li\u003e\n\u003cli\u003eGEI-100488 technical manual documentation\u003c\/li\u003e\n\u003cli\u003eInstallation and commissioning guidelines\u003c\/li\u003e\n\u003cli\u003eQuality verification and testing certificate\u003c\/li\u003e\n\u003cli\u003eProtective anti-static packaging materials\u003c\/li\u003e\n\u003cli\u003eHardware and mounting accessories\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping \u0026amp; Logistics Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eExpress worldwide shipping via FedEx, UPS, DHL\u003c\/li\u003e\n\u003cli\u003eProfessional industrial packaging standards\u003c\/li\u003e\n\u003cli\u003eTracking information provided for all shipments\u003c\/li\u003e\n\u003cli\u003eCustoms documentation preparation service\u003c\/li\u003e\n\u003cli\u003eInsurance coverage available for high-value shipments\u003c\/li\u003e\n\u003cli\u003eQuick order processing and dispatch system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProfessional FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2e74b5;\"\u003eWhat is the primary function of the voltage attenuator circuit?\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eThe voltage attenuator measures and regulates field voltage precisely. It provides differential voltage feedback to the ERDD board for accurate excitation control.\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2e74b5;\"\u003eCan this converter operate with both AC and DC power inputs?\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eYes, the unit accepts rectified AC power, station battery DC power, or combined input sources. This flexibility ensures reliable operation in various power scenarios.\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2e74b5;\"\u003eHow does the field discharge functionality work during operation?\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eOne IGBT module handles field discharge operations. It safely dissipates field energy during system shutdown or redundant switchover transitions.\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2e74b5;\"\u003eWhat maintenance procedures does this static converter require?\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eRegular inspection of IGBT connections and heat sink cleanliness is essential. Periodic verification of solder joints and power connections ensures long-term reliability.\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2e74b5;\"\u003eHow does the K3 relay enhance system functionality?\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eThe K3 relay bypasses the DC link charging resistor during specific operations. This feature optimizes system performance and protects components from inrush currents.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty \u0026amp; Technical Support\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e12-month comprehensive product warranty\u003c\/li\u003e\n\u003cli\u003eTechnical support for installation and troubleshooting\u003c\/li\u003e\n\u003cli\u003eApplication engineering assistance available\u003c\/li\u003e\n\u003cli\u003eReplacement service for qualified warranty claims\u003c\/li\u003e\n\u003cli\u003eDocumentation and manual access provided\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2025 Ubest Automation Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.ubestplc.com\/\"\u003ehttps:\/\/www.ubestplc.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@ubestplc.com\"\u003esales@ubestplc.com\u003c\/a\u003e Phone: \u003ca href=\"https:\/\/wa.me\/86180030005825\"\u003e+86 180 3000 5825\u003c\/a\u003e\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":51236473930010,"sku":"IS200ERSCG1AAA","price":148.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/IS200ERSCG1AAA.jpg?v=1761267055","url":"https:\/\/www.ubestplc.com\/pt\/products\/ge-exciter-regulator-static-converter-is200erscg1aaa","provider":"Ubest Automation Limited","version":"1.0","type":"link"}