{"product_id":"allen-bradley-micrologix-1200-plc-16-relay-outputs-1762-l40awa","title":"Allen-Bradley MicroLogix 1200 PLC 16 Relay Outputs 1762-L40AWA","description":"\u003ch2\u003eAllen-Bradley 1762-L40AWA: High-Density MicroLogix 1200 Controller\u003c\/h2\u003e\n\u003cp\u003eThe Allen-Bradley \u003cstrong\u003e1762-L40AWA\u003c\/strong\u003e delivers powerful automation control with its extensive I\/O count. For complete wiring, programming, and specification details, download the full technical bulletin now.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/MicroLogix_1200_Bulletin_1762_Controllers_and_IO.pdf?v=1760058069\"\u003eDownload Complete Technical Manual (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct Overview \u0026amp; Key Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eSeries:\u003c\/span\u003e MicroLogix 1200 Programmable Logic Controller\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eManufacturer:\u003c\/span\u003e Rockwell Automation \/ Allen-Bradley\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eI\/O Capacity:\u003c\/span\u003e 24 Inputs and 16 Outputs for 40 total channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eIntegrated Tools:\u003c\/span\u003e Two front-panel trim potentiometers for easy adjustment\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eCommunication:\u003c\/span\u003e 8-pin mini-DIN port supporting multiple protocols\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDetailed Electrical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eInput Power:\u003c\/span\u003e 120-240V AC, 47-63 Hz operating frequency\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eInput Signals:\u003c\/span\u003e 24 channels rated for 120V AC operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eOn-State Voltage:\u003c\/span\u003e 14-24V DC for inputs 0-3; 10-24V DC for inputs 4+\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eOff-State Voltage:\u003c\/span\u003e 0-5V DC maximum with 1.5 mA leakage current\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003ePower Consumption:\u003c\/span\u003e 82 VA with inrush current protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOutput Performance \u0026amp; Ratings\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eOutput Type:\u003c\/span\u003e 16 Form C relay contacts for maximum flexibility\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eContact Rating:\u003c\/span\u003e 10A minimum at 24-125VDC or 120-240VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eTotal Load Capacity:\u003c\/span\u003e Controls loads up to 1440 VA maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eCurrent Limit:\u003c\/span\u003e 8 Amps per group common connection\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eMechanical Life:\u003c\/span\u003e 20 million operational cycles minimum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical \u0026amp; Environmental Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eDimensions:\u003c\/span\u003e 160mm W x 90mm H x 87mm D (104mm H with latch)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eOperating Temperature:\u003c\/span\u003e 0°C to 55°C (32°F to 131°F) ambient range\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eShipping Weight:\u003c\/span\u003e 2.4 pounds for easy handling and installation\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eCommunication Protocols:\u003c\/span\u003e DF1, DH-485, ASCII, and MODBUS Master\/Slave\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackaging \u0026amp; Delivery Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eYour order includes one \u003cstrong\u003e1762-L40AWA\u003c\/strong\u003e controller unit\u003c\/li\u003e\n\u003cli\u003eAll shipments include necessary documentation and hardware\u003c\/li\u003e\n\u003cli\u003eWe ship worldwide via FedEx, UPS, and DHL express carriers\u003c\/li\u003e\n\u003cli\u003eStandard lead time is 1-3 business days for order processing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty \u0026amp; Support\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAll products include comprehensive 12-month warranty coverage\u003c\/li\u003e\n\u003cli\u003eOur technical support team provides expert installation guidance\u003c\/li\u003e\n\u003cli\u003eWarranty protects against manufacturing defects and component failures\u003c\/li\u003e\n\u003cli\u003eWe guarantee replacement for any unit failing under normal use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProfessional FAQs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2e74b5;\"\u003eWhat is the maximum load current per output relay?\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eEach relay contact can handle 10 amps continuously at 240V AC.\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2e74b5;\"\u003eHow do the front-panel potentiometers function?\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eThe two trim pots simulate internal registers or control process variables directly.\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2e74b5;\"\u003eWhat communication protocols does the serial port support?\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eThe 8-pin mini-DIN port runs DF1, DH-485, ASCII, and MODBUS protocols.\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2e74b5;\"\u003eWhat is the inrush current specification?\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eThe controller handles 25A for 8ms at 120V AC and 40A for 4ms at 240V AC.\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2e74b5;\"\u003eCan I use all 16 relay outputs simultaneously at full load?\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eYou must observe the 8A per group common limit and 1440 VA total capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2025 Ubest Automation Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.ubestplc.com\/\"\u003ehttps:\/\/www.ubestplc.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@ubestplc.com\"\u003esales@ubestplc.com\u003c\/a\u003e Phone: \u003ca href=\"https:\/\/wa.me\/868618030005825\"\u003e+86 86 180 3000 5825\u003c\/a\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51182705803546,"sku":null,"price":166.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/1762-L40AWA_3.jpg?v=1760058430","url":"https:\/\/www.ubestplc.com\/ru\/products\/allen-bradley-micrologix-1200-plc-16-relay-outputs-1762-l40awa","provider":"Ubest Automation Limited","version":"1.0","type":"link"}