Bently Nevada Temperature Monitor - 3500/61-04-01

Na sklade
Manufacturer:
Bently Nevada
Product No.:
3500/61-04-01
Condition:
In Stock
Product Type:
Temperature Monitor
Product Origin:
USA
Weight:
500g
Shipping port:
Xiamen
Warranty:
12 months

UBEST – dôveryhodný globálny dodávateľ náhradných dielov pre automatizáciu

Ponúkame široký sortiment skladových náhradných dielov pre priemyselnú automatizáciu. Všetky produkty majú 12-mesačnú záruku a 30-dňovú možnosť vrátenia peňazí pri problémoch s kvalitou.

O nás | Kontakt

Bently Nevada 3500/61-04-01 Temperature Monitoring System

The Bently Nevada 3500/61-04-01 temperature monitor provides precise thermal measurement for industrial machinery. This advanced system supports multiple sensor types and offers reliable performance in demanding environments.

Key Features and Benefits

  • Supports 1 to 6 RTD or thermocouple input signals simultaneously
  • Isolated I/O module ensures accurate measurements and safety
  • Class 1 Division 2 certification for hazardous area operation
  • Multiple thermocouple types including E, J, K, and T varieties
  • High-resolution measurement with 1°C or 1°F precision
  • Programmable alarm setpoints with adjustable time delays
  • Recorder outputs provide 4-20mA signals for data logging

Complete Technical Specifications

  • Brand: Bently Nevada
  • Model: 3500/61-04-01
  • Product Type: Temperature Monitor with Recorder Outputs
  • Power Consumption: 9 watts nominal operation
  • Input Impedance: 10 MΩ for each lead input
  • RTD Current Source: 925±15 μA per transducer
  • Recorder Output: 4 to 20mA proportional to full-scale
  • Voltage Compliance: 0 to +12Vdc across 0-600Ω load
  • Operating Temperature: -30°C to +65°C standard
  • Storage Temperature: -40°C to +85°C range
  • System Isolation: 500Vdc protection
  • Channel Isolation: 250Vdc between channels
  • Manufacturing Origin: Made in U.S.A.

Sensor Type Compatibility

  • Type E Thermocouple: -100°C to +1000°C range
  • Type J Thermocouple: -18°C to +760°C operation
  • Type K Thermocouple: -18°C to +1370°C capability
  • Type T Thermocouple: -160°C to +400°C measurement
  • 100Ω Platinum RTD: -200°C to +850°C with 0.00385 alpha
  • 100Ω Platinum RTD: -200°C to +700°C with 0.00392 alpha
  • 120Ω Nickel RTD: -80°C to +260°C temperature range
  • 10Ω Copper RTD: -100°C to +260°C measurement capability

Model Number Structure

  • Product Series: 3500/61 Temperature Monitor
  • I/O Module: 04 - TC Isolated I/O Module External
  • Agency Approval: 01 - CSA/NRTL/C Class 1 Division 2

Measurement Accuracy

  • Standard RTD/TC Resolution: 1°C or 1°F precision
  • Internal Termination Accuracy: ±3°C at 25°C
  • External Termination Accuracy: ±1°C at 25°C
  • Copper RTD Accuracy: ±3°C at 25°C temperature
  • Cold Junction Compensation: ±1°C at 25°C precision
  • Alarm Setpoint Accuracy: Within 0.13% of desired value

Alarm and Safety Features

  • Programmable Alert and Danger setpoints for each channel
  • Adjustable alarm delays from 1 to 60 seconds
  • Danger alarm delays in 0.5 second intervals
  • Both under and over temperature alarm capabilities
  • Front panel LEDs indicate operational status
  • Bypass mode LED shows manual override condition

Physical Dimensions

  • Monitor Module: 241mm x 24mm x 242mm compact size
  • Monitor Weight: 0.91kg lightweight construction
  • I/O Module: 241mm x 24mm x 99mm standard dimensions
  • I/O Module Weight: 0.45kg easy installation
  • Internal Barrier Module: 241mm x 24mm x 163mm size
  • Internal Barrier Weight: 0.46kg robust design

Installation Requirements

  • Requires one full-height front slot for monitor module
  • Needs one full-height rear slot for I/O module
  • 3500 Configuration Software for field setup
  • No calibration required during installation
  • Supports internal and external termination options
  • Works with bulkhead rack and standard rack configurations

Shipping Information

  • New original equipment in factory packaging
  • Express delivery via FedEx, UPS, and DHL carriers
  • International shipping available worldwide
  • Professional packaging for industrial equipment protection

Frequently Asked Questions

  • How many temperature sensors can this monitor support?
  • The system accepts up to six RTD or thermocouple input signals.
  • What types of thermocouples are compatible?
  • It supports Type E, J, K, and T thermocouple varieties.
  • Can this monitor operate in hazardous areas?
  • Yes, it carries Class 1 Division 2 certification for hazardous locations.
  • What is the temperature measurement resolution?
  • The system provides 1°C or 1°F resolution for precise monitoring.
  • Does this require field calibration after installation?
  • No calibration is required when using the configuration software.

Contact Our Technical Team

Email sales@ubestplc.com for product specifications. Call +86 180 3000 5825 for immediate WhatsApp support.