Allen Bradley PowerFlex 753 AC Drive 20F11ND096AA0NNNNN
The Allen Bradley 20F11ND096AA0NNNNN is a versatile adjustable frequency AC drive from the PowerFlex 753 series. This model provides robust motor control for industrial applications up to 75 horsepower. It features embedded I/O, an internal dynamic brake transistor, and built-in EMC filtering. The 20F11ND096AA0NNNNN offers flexible connectivity with an optional communication slot for network integration.
Drive Identification & Power Ratings
- Brand: Allen Bradley (Rockwell Automation)
- Model: 20F11ND096AA0NNNNN
- Series: PowerFlex 753 AC Drive
- Input Power: Three-Phase, 480 V AC (50/60 Hz) or 650 V DC
- Output Power (Normal Duty): 55 kW / 75 HP
- Output Power (Heavy Duty): 45 kW / 60 HP
- Output Current (ND): 96 Amps
- Output Current (HD): 77 Amps
- Output Frequency Range: 0 to 590 Hz
- Control Method: Sensorless Vector Control, Volts/Hertz (V/Hz)
Key Features & Internal Components
- Embedded I/O: Includes digital and analog inputs/outputs for basic control.
- Dynamic Braking: Integrated DB Transistor for fast motor stopping.
- EMC Compliance: Built-in RFI filter for conducted emissions per IEC 61800-3.
- Common Mode Jumper: Removed in this configuration for specific installation requirements.
- Cooling Method: Internal Fan, Air Cooled
- Communication: Optional slot for add-on communication adapters (e.g., EtherNet/IP, DeviceNet).
- Human Interface Module (HIM): Not included (blanking plate installed).
Physical & Environmental Specifications
- Enclosure Type: Open Type (Chassis)
- Mounting Style: Panel Mount
- Frame Size: Frame 5
- Ingress Protection (IP): IP20 (front)/IP00 (chassis) for indoor cabinet use.
- Operating Temperature: 0°C to 50°C (32°F to 122°F) with derating above 40°C.
- Storage Temperature: -40°C to 85°C (-40°F to 185°F)
- Relative Humidity: 5% to 95% (non-condensing)
- Operating Altitude: 0-1000 meters without derating; derate 1% per 100m above 1000m.
- Vibration Resistance: 1.0 G from 2 to 200 Hz per IEC 60068-2-6.
- Unit Weight: 38.56 kg (85.00 lbs)
Electrical Performance & Protection
- Overload Capacity: 150% of rated current for 60 seconds (Heavy Duty rating).
- Starting Torque: Up to 200% of motor rated torque in sensorless vector mode.
- Speed Regulation: ±0.5% of base speed (sensorless vector).
- Efficiency: Typically > 97.5%.
- Protections: Motor overload, overcurrent, overvoltage, undervoltage, ground fault, short circuit, heat sink overtemperature.
- DC Bus Connections: Terminals provided for connecting a DC power source or bus.
Installation & Mounting Requirements
- Mount the drive vertically on a solid, flat panel within an enclosed electrical cabinet.
- Maintain the specified clearance around the drive (top, bottom, sides) for proper airflow.
- Use copper conductors only for all power and control wiring.
- Connect the motor leads (U, V, W) directly to the drive's output terminals.
- Install an appropriately rated disconnect switch and fuses or circuit breaker upstream.
- Ground the drive chassis securely using the designated PE (Protective Earth) terminal.
- For EMC compliance, use shielded motor cable and ground the shield at the drive end.
- Configure motor nameplate data and application parameters via a connected HIM or software.
Packaging & Shipping Details
- Package Contents: 1 x Allen Bradley 20F11ND096AA0NNNNN Drive Unit (Open Chassis)
- Documentation: Quick Start guide may be included; full manual available online.
- Shipping Weight: Approximately 40 kg (88 lbs) including packaging material.
- Shipping Methods: Available for shipping via FedEx, UPS, or DHL freight services.
- Handling: Use appropriate lifting equipment due to the unit's significant weight.
Warranty Information
- Coverage Period: 12 months from the original purchase date.
- The warranty covers failures resulting from defects in materials or component workmanship.
- Proper installation within the published environmental and electrical limits is required.
- Technical support is available to assist with setup and troubleshooting procedures.
Frequently Asked Questions (FAQ)
- What does "Normal Duty" vs. "Heavy Duty" mean for this drive?
Normal Duty (ND) ratings are for typical variable torque loads like fans and pumps, allowing higher horsepower. Heavy Duty (HD) ratings are for constant torque, high-cycling applications like conveyors, which require more thermal capacity at a lower horsepower.
- Why is the Common Mode Jumper removed on this model?
Removing the CM jumper is a specific configuration for installations where you are using an external RFI filter or have special grounding requirements to meet stringent EMC standards. It helps manage common-mode noise currents in the system.
- Can I run a 480V motor directly on 400V supply with this drive?
No, the input voltage must match the drive's rating. This 480V AC drive requires a 480V (+10%/-10%) supply. Running it on 400V will cause an undervoltage fault. You must select a drive model rated for your specific supply voltage.
- How do I program the drive without the Human Interface Module (HIM)?
You can use Rockwell's Connected Components Workbench (CCW) software free of charge. Connect a computer to the drive's embedded serial port (DSI) using a 1203-USB or similar communication cable to configure all parameters.
- Is the internal DB transistor sufficient for my high-inertia stopping application?
The internal transistor can handle moderate braking energy. For high inertia or rapid cycle braking, you must connect an external braking resistor to the drive's DB terminals. The drive will calculate and display braking resistor requirements during setup.