Engineered for extreme conditions, this 3300 XL armored extension cable provides maximum durability. The 330190-075-00-CN combines mechanical protection with precise signal transmission for critical monitoring applications.
Product Overview & Key Features
- Manufacturer: Bently Nevada
- Product Series: 3300 XL Vibration Monitoring System
- Model Number: 330190-075-00-CN
- Cable Type: Armored Extended Temperature Range (ETR)
- Construction: 75Ω Triaxial with PFA Insulation
- Armor Material: Corrugated stainless steel for crush protection
- Jacket Material: Polyurethane for abrasion resistance
- Country Approval: CN specific certification included
Electrical Performance Specifications
- Center Conductor Resistance: 1.65 Ω ± 0.25 at 20°C
- Outer Shield Resistance: 0.49 Ω ± 0.10 at 20°C
- Capacitance Core-to-Shield: 69.9 pF/m typical
- Characteristic Impedance: 75Ω ±5% from 1-100 MHz
- Dielectric Withstanding Voltage: 1500 Vrms for 60 seconds
- Insulation Resistance: ≥5000 MΩ per kilometer at 500 VDC
- Signal Bandwidth: DC to 15 kHz (-3 dB point)
Mechanical & Physical Properties
- Cable Length: 7.5 meters (24.6 feet) exact length
- Cable Outer Diameter: 6.2 mm with armor protection
- Minimum Bend Radius: 50 mm (2.0 inches) under tension
- Cable Weight: 103 g/m (1.5 oz/ft) armored version
- Connector Type: Gold-plated triaxial 8mm design
- Mating Cycles: ≥500 cycles without performance degradation
- Crush Resistance: Withstands 2000 N/cm crushing force
Environmental & Operating Conditions
- Temperature Range: -52°C to +260°C continuous operation
- Thermal Cycling: 1000 cycles from -55°C to +260°C
- Humidity Resistance: 95% RH at 65°C for 1000 hours
- Oil Resistance: Compatible with lubricating oils and fuels
- Chemical Resistance: Resists acids, alkalis, and solvents
- Flame Rating: IEC 60332-1-2 flame retardant certified
- UV Resistance: Suitable for outdoor installation
Measurement System Performance
- Linear Range: 0.25 mm to 2.3 mm from target surface
- Recommended Gap: 1.27 mm (50 mils) for -9 VDC output
- System Sensitivity: 7.87 V/mm (200 mV/mil) standard
- Nonlinearity: <±1% over entire linear range
- Temperature Coefficient: ±0.05%/°C over operating range
- Hysteresis: <0.5% of full scale output
- Resolution: Better than 0.1 μm (4 μinches)
Installation Requirements
- Field Wiring: 0.2 to 1.5 mm² (16-24 AWG) shielded triad
- Maximum Distance: 305 meters between sensor and monitor
- Wiring Preparation: Use tinned copper conductors only
- Shielding: Continuous 360° shield termination required
- Grounding: Single-point ground at monitor location
- Separation: Keep 300 mm from power cables
- Strain Relief: Provide within 150 mm of connector
Compliance & Safety Information
- Functional Safety: SIL 2 (HFT=0) and SIL 3 (HFT=1) capable
- EMC Immunity: EN 61000-6-2 for industrial environments
- EMC Emissions: EN 61000-6-4 Class A requirements
- Maritime Approval: ABS, DNV, LR, and BV certified
- RoHS Compliance: 2011/65/EU without exemptions
- Vibration Test: IEC 60068-2-6, 10g, 10-2000 Hz
- Shock Test: IEC 60068-2-27, 50g, 11 ms duration
Shipping & Delivery Information
- Packaging: Individual protective tube with end caps
- Documentation: Includes test certificate and data sheet
- Shipping Methods: FedEx, UPS, DHL express available
- Lead Time: Standard stock to 4 weeks for reliability
- Order Verification: Includes serialized test records
Technical Support FAQ
- What advantage does armored cable provide over standard?
- Armored construction adds crush protection and durability in harsh plants.
- Can this cable withstand direct burial applications?
- No, the armored version needs conduit for direct burial installation.
- What maintenance does this extension cable require?
- Regular inspection for physical damage and connector integrity checks.
- How does temperature affect cable resistance values?
- Resistance increases approximately 0.4% per °C temperature rise.
- What tools are needed for proper connector installation?
- Use torque wrench and proper triaxial connector tool kit only.