{"product_id":"allen-bradley-1762-l40bwar-micrologix-1200-plc-16-relays","title":"Allen-Bradley 1762-L40BWAR MicroLogix 1200 PLC - 16 Relays","description":"\u003ch2\u003eAllen-Bradley 1762-L40BWAR: Advanced MicroLogix 1200 Controller\u003c\/h2\u003e\n\u003cp\u003eThe Allen-Bradley \u003cstrong\u003e1762-L40BWAR\u003c\/strong\u003e delivers exceptional performance for industrial automation applications. This MicroLogix 1200 series PLC from Rockwell Automation features advanced connectivity and robust I\/O capabilities. It offers 24 digital inputs including four high-speed inputs and sixteen relay outputs. Access the complete technical documentation to explore all features and specifications in detail.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/MicroLogix_1200_Bulletin_1762_Controllers_and_IO.pdf?v=1760058069\"\u003eDownload Full Technical Manual Here\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eComprehensive Technical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eBrand \u0026amp; Model:\u003c\/span\u003e Allen-Bradley \u003cstrong\u003e1762-L40BWAR\u003c\/strong\u003e MicroLogix 1200\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eInput Power:\u003c\/span\u003e 120-240V AC, 47-63 Hz operating frequency\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eDigital Inputs:\u003c\/span\u003e 20 standard 24V DC + 4 fast 24V DC inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eOutput Configuration:\u003c\/span\u003e 16 relay outputs with Form C contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eContact Rating:\u003c\/span\u003e 10A at 24-125VDC \/ 120-240VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003ePower Consumption:\u003c\/span\u003e 82 VA with 22W heat dissipation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommunication \u0026amp; Connectivity Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003ePrimary Port:\u003c\/span\u003e 8-pin mini-DIN for HMI and SCADA systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eProgramming Port:\u003c\/span\u003e Dedicated 8-pin mini-DIN for online editing\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eSupported Protocols:\u003c\/span\u003e DF1, DH-485, ASCII, MODBUS Master\/Slave\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eSimultaneous Operation:\u003c\/span\u003e Both ports function independently\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eSensor Power:\u003c\/span\u003e 24V DC source with 400 mA maximum capacity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePerformance \u0026amp; Environmental Ratings\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eOperating Temperature:\u003c\/span\u003e 0°C to 55°C (32°F to 131°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eStorage Temperature:\u003c\/span\u003e -40°C to 85°C (-40°F to 185°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eMechanical Endurance:\u003c\/span\u003e 20 million mechanical cycles\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eInrush Current:\u003c\/span\u003e 25A\/8ms at 120V AC, 40A\/4ms at 240V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eInput Type:\u003c\/span\u003e 24V DC sink\/source with optical isolation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Wiring Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUse separate power sources for outputs and sensor supply circuits\u003c\/li\u003e\n\u003cli\u003eThe sensor supply COM connects internally to chassis ground\u003c\/li\u003e\n\u003cli\u003eDo not use the 24V DC sensor power for output circuits\u003c\/li\u003e\n\u003cli\u003eMaintain proper clearance for heat dissipation during operation\u003c\/li\u003e\n\u003cli\u003eFollow agency certifications including UL 508 and CE directives\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackaging \u0026amp; Shipping Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFactory-new \u003cstrong\u003e1762-L40BWAR\u003c\/strong\u003e controller unit\u003c\/li\u003e\n\u003cli\u003eComplete installation and programming documentation\u003c\/li\u003e\n\u003cli\u003eInternational shipping via FedEx, UPS, and DHL available\u003c\/li\u003e\n\u003cli\u003eStandard packaging ensures secure transit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty \u0026amp; Support Coverage\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eComprehensive 12-month product warranty included\u003c\/li\u003e\n\u003cli\u003eProfessional technical support for installation assistance\u003c\/li\u003e\n\u003cli\u003eWarranty covers all manufacturing defects and components\u003c\/li\u003e\n\u003cli\u003eQuick replacement service for qualified warranty claims\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eExpert Frequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2e74b5;\"\u003eWhat is the difference between standard and fast inputs?\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eThe four fast inputs (channels 0-3) support higher frequency applications.\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2e74b5;\"\u003eCan both communication ports be used simultaneously?\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eYes, both ports operate independently for maximum flexibility.\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2e74b5;\"\u003eWhat is the maximum sensor power capacity?\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eThe 24V DC sensor supply provides 400 mA with 400 μF maximum.\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2e74b5;\"\u003eHow does the sink\/source input configuration work?\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eThe inputs accept both sinking and sourcing field device wiring.\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #2e74b5;\"\u003eWhat safety certifications does this controller have?\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eIt carries UL 508, Class I Div 2, CE, RCM, and EAC certifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2025 Ubest Automation Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.ubestplc.com\/\"\u003ehttps:\/\/www.ubestplc.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@ubestplc.com\"\u003esales@ubestplc.com\u003c\/a\u003e Phone: \u003ca href=\"https:\/\/wa.me\/868618030005825\"\u003e+86 86 180 3000 5825\u003c\/a\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51182721794330,"sku":null,"price":157.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/1762-L40BWAR_3.jpg?v=1760058430","url":"https:\/\/www.ubestplc.com\/tr\/products\/allen-bradley-1762-l40bwar-micrologix-1200-plc-16-relays","provider":"Ubest Automation Limited","version":"1.0","type":"link"}