GE Acoustic Monitoring Board | Mark VI IS200TAMBH1ACB
UBEST – Proveedor Global de Piezas de Automatización Confiable
Ofrecemos una amplia gama de piezas de repuesto para automatización industrial en stock. Todos los productos cuentan con una garantía de 12 meses y un reembolso de 30 días por problemas de calidad.
GE IS200TAMBH1ACB Acoustic Monitoring Terminal Board for Industrial Applications
The IS200TAMBH1ACB delivers advanced acoustic monitoring capabilities for General Electric's Mark VI control systems. This sophisticated terminal board provides comprehensive signal processing and power management for industrial acoustic analysis. It ensures reliable operation through flexible configuration options and robust diagnostic features.
Technical Specifications & Performance Data
- Manufacturer: General Electric
- Model Number: IS200TAMBH1ACB
- Product Type: Acoustic Monitoring Terminal Board
- Control System Series: Mark VI
- Operating Temperature Range: -30°C to +65°C
- Monitoring Channels: 9 independent acoustic channels
- Power Supply Output: Dual 24V DC per channel
- Current Limiting: Programmable current protection
- Input Signal Types: 4-20mA current or voltage input
- Burden Resistor: 250 ohm for current input mode
- Signal Resolution: 16-bit analog-to-digital conversion
- Sampling Rate: 100 kS/s per channel maximum
- Frequency Response: 10 Hz to 50 kHz ±1dB
- Input Impedance: 1M ohm for voltage inputs
- Common Mode Rejection: >80 dB at 60 Hz
- Noise Performance: <10 μV RMS typical
Multi-Channel Power Management System
- Nine independent channels provide individual acoustic monitoring paths
- Each channel features dual 24V DC power supply outputs for redundancy
- Current-limited outputs prevent sensor damage during overload conditions
- Standard 24V DC outputs ensure continuous operation during faults
- Power common (PCOM) connections maintain stable reference voltages
Advanced Signal Processing Capabilities
- Constant current sources maintain stable sensor excitation levels
- CCSELx control signals activate current sources from VAMB boards
- Automatic initialization sequences prevent false readings at startup
- High-impedance DC bias enables open circuit detection capability
- Signal integrity monitoring identifies sensor connection issues
Flexible Input Configuration Options
- Hardware jumpers select between current and voltage input modes
- Current input mode utilizes 250 ohm burden resistors for 4-20mA signals
- Voltage input mode accepts direct voltage measurements from sensors
- Return line jumpers configure PCOM connections for noise reduction
- Isolated return paths prevent ground loop interference issues
Diagnostic & Monitoring Features
- Open circuit detection identifies broken sensor connections immediately
- High-impedance monitoring detects signal path discontinuities
- Automatic fault reporting to VAMB vibration monitoring systems
- Continuous health monitoring of all nine acoustic channels
- Real-time signal quality assessment during normal operation
Installation & Configuration Guide
- Mount the terminal board in designated Mark VI system locations
- Connect acoustic sensors to appropriate channel input terminals
- Set JPx jumpers for current or voltage input mode requirements
- Configure return line jumpers for PCOM connection preferences
- Verify all power supply connections meet 24V DC specifications
- Establish communication links with VAMB monitoring boards
- Test each channel for proper signal acquisition and processing
- Validate open circuit detection functionality during commissioning
System Integration & Compatibility
- Seamless integration with Vibration Acoustic Monitoring Board systems
- Compatible with various industrial acoustic sensor types and brands
- Direct interface with Mark VI control system architecture
- Supports both standalone and distributed monitoring applications
- Flexible configuration for different industrial environments
Packaging & Shipping Details
- Factory-new IS200TAMBH1ACB acoustic monitoring board
- Anti-static protective packaging ensures component safety
- All necessary mounting hardware and jumpers included
- Global express shipping via FedEx, UPS, and DHL carriers
- Professional documentation and installation guidelines provided
Expert Technical Support
- What input signal types does the TAMB board support?
- The board accepts both 4-20mA current loop signals and voltage inputs from 0-10V range with jumper-selectable configuration for each channel
- How does the open circuit detection feature work?
- A high-impedance DC bias monitors signal paths continuously, detecting voltage level changes that indicate broken connections or sensor failures
- Can I mix different sensor types on the same board?
- Yes, each of the nine channels configures independently, allowing current and voltage sensors to operate simultaneously on the same terminal board
- What is the purpose of the dual power supply outputs?
- Dual outputs provide redundancy and current-limited protection, ensuring continuous operation even if one power path experiences issues or overload conditions
- How do I configure the return line connections?
- Odd-numbered JPx jumpers select between PCOM reference or isolated return paths to optimize signal quality and prevent ground loop problems
© 2025 Ubest Automation Limited. All rights reserved.
Original Source: https://www.ubestplc.com/
Contact: sales@ubestplc.com Tel: +86 180 3000 5825