K-LE200-EIP-1 Laser Measuring Device LE-200 – TR Electronic
Core Measurement Performance
- Model K-LE200-EIP-1 Laser Measuring Device LE-200 offers 195 meters max range with reflector foil.
- 0.1 mm physical resolution ensures precise positioning control.
- Linearity deviation: ±3 mm absolute up to 12 m, ±5 mm FS for full scale.
- Reproducibility stays within ±2 mm for reliable repeated measurements.
- Refresh rate reaches 1000 values per second with only 1 ms integration time.
Electrical Supply & Laser Safety
- Supply voltage range: 18…27 VDC ±5%, no-load current ≤350 mA.
- Integrated heating option: 24 VDC ±5% at 48 W nominal power.
- Laser source: red light diode, wavelength 670 nm, radiant power ≤1 mW (Class 2).
- Safety standards: IEC 60825-1 and FDA 21CFR 1040.10 / 1040.11 (Laser Notice No. 50).
- Minimum operation time >30 minutes guarantees all specifications.
EtherNet/IP™ Interface & Programmability
- Physical layer: Fast Ethernet at 100 MBit/s (ISO/IEC 8802-3).
- Device profile: Encoder Device Profile 0x22 per IEC 61784-1 CP 2/2.
- Programmable parameters: addressing, resolution, error outputs, intensity, preset, temperature, counting direction, velocity.
- Programming tool: TRWinProg (TR-Soft) or any fieldbus device tool.
- External inputs (1x): preset adjustment, laser diode shut-off, error acknowledgement.
- External outputs (1x): status for temperature, intensity, hardware, speed, position.
- Logic levels: LOW “0” < +2 V (≤ ±35 V, 5 kOhm); HIGH “1” > +8 V for inputs. Outputs: LOW < 1 V (≤100 mA), HIGH > Supply Voltage -2 V.
Environmental Toughness & Protection
- Working temperature: standard 0…+50 °C or optional -30…+50 °C.
- Storage temperature (dry): -20…+75 °C. Humidity tolerance: 98% non-condensing.
- Vibration resistance: ≤50 m/s² (50…2000 Hz sine). Shock resistance: ≤300 m/s² (half sine 11 ms).
- Immunity to disturbance per DIN EN 61000-6-2; emissions per DIN EN 61000-6-3.
- Protection class: IP65 standard – dust-tight and water-jet resistant.
- Temperature drift: 1 ppm/°C for all ranges (125 m, 170 m, 195 m).
Frequently Asked Questions (FAQ)
-
Q: Can the K-LE200-EIP-1 work outdoors?
A: Yes, with IP65 rating and optional -30°C version. Avoid direct water jets. -
Q: Does this device need a reflector?
A: Yes. Phase shift measurement requires the supplied reflector foil for full 195m range. -
Q: How do I change the counting direction?
A: Use TRWinProg or programmable parameter via EtherNet/IP – simple and flexible. -
Q: What happens during a connection timeout?
A: The Error LED flashes 1 Hz. Re-establish connections or power cycle the device. -
Q: Is the laser safe for operators?
A: Yes, Class 2 laser (≤1 mW) with international safety certifications IEC/FDA.