Honeywell XNX-AMSV-NHCB1 Gas Detector - Buy Online Today

In stock
Manufacturer:
Honeywell
Product No.:
XNX-AMSV-NHCB1
Condition:
In Stock
Product Type:
Universal Gas Transmitter
Product Origin:
USA
Weight:
6500g
Shipping port:
Xiamen
Warranty:
12 months

UBEST – Trusted Global Automation Parts Supplier

We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.

About Us | Contact

Honeywell XNX-AMSV-NHCB1 Universal Gas Transmitter Architectural Guide

Plant operators run flammable gas monitoring loops efficiently by using the Honeywell XNX-AMSV-NHCB1 universal transmitter across hazardous chemical facilities. The flexible XNX platform integrates high-precision MPD catalytic bead sensors directly into plant control networks to detect combustible leaks.

Download full technical documentation from Honeywell XNX Universal Transmitter Manual for complete field installation rules and wiring steps.

Download Official Product Manual (PDF)

Summary

  • The XNX-AMSV-NHCB1 transmitter monitors combustible gases across a 0–100% LEL range with extreme precision.
  • Engineers specify this Honeywell XNX-AMSV-NHCB1 unit because painted 316 stainless steel housings resist severe outdoor climate conditions.
  • Operators configure local parameters easily using the onboard display and built-in local HART communication ports.
  • Maintenance crews replace smart sensor modules quickly without de-energizing main electrical circuits in hazardous zones.

Technical Specifications

  • Brand: Honeywell Analytics
  • Model: XNX-AMSV-NHCB1
  • Subcategory: Universal Gas Transmitter / Flammable Gas Detection
  • Measurement Range: 0–100% LEL combustible lower explosive limit
  • Sensor Technology: MPD catalytic bead flammable gas sensor
  • Frequency Response: T90 under 12 seconds for fast hazard detection
  • Signal Sensitivity: High accuracy response with stable zero baseline tracking
  • Measurement Linearity: Exceptional linear accuracy across full 100% LEL scale
  • Display Resolution: 1% LEL resolution increments on backlit LCD screen
  • Operating Temperature: –40 °C to +65 °C (–40 °F to +149 °F)
  • Environmental Tolerance: IP66 weatherproofing rating for harsh industrial environments
  • Interference Immunity: Advanced electronic filtering suppresses surrounding electromagnetic field noise
  • Signal Output: 4–20 mA loop with HART EDDL digital overlay protocol
  • Conduit Entry Threads: Metric M25 entry ports for international gland connection
  • Enclosure Material: 316 painted stainless steel heavy-duty construction
  • Hazardous Approvals: ATEX, IECEx, and INMETRO Zone 1 certifications

Model Code Tree Analysis

  • XNX Series: Universal Gas Detection Transmitter Platform
    • A: ATEX / IECEx European and Global Explosion-Proof Approvals
      • M: MPD Catalytic Bead Combustible Sensor Input Interface
        • S: SS316 Painted Stainless Steel Rugged Housing
          • V: Metric M25 Conduit Gland Port Connection Size
            • N: Standard Unit Configuration Without Local Option Card
              • H: HART Digital Protocol Output Communication Interface
                • C: Local HART External Test Connection Port
                  • B: MPD Flammable Catalytic Sensor Cell Included
                    • 1: 0–100% LEL Standard Methane / Hydrocarbon Calibration

Model Comparison & Technical Selection Advice

  • XNX-AMSV-NHCB1 features an ATEX M25 stainless steel housing for flammable LEL gas monitoring.
  • The alternative model XNX-UTSE-RHCB1 utilizes UL/CSA approvals with 3/4" NPT conduit entries and internal relay outputs instead.
  • Select metric M25 entries when wiring installations follow European ATEX gland design standards.
  • Choose NPT thread versions when mounting transmitters inside North American conduit runs.

Installation Guidelines

  • Mount the transmitter housing securely onto solid wall surfaces or structural steel pipes.
  • Screw explosion-proof M25 cable glands directly into enclosure ports using approved thread sealant.
  • Wire power lines strictly according to terminal block markings inside the main junction chamber.
  • Attach external earthing cables to internal grounding terminals to prevent static charge buildup.

Packaging List & Shipping Details

  • 1 x Honeywell XNX-AMSV-NHCB1 Stainless Steel Universal Transmitter Assembly
  • 1 x Integrated MPD Flammable Catalytic Bead Sensor Module
  • 1 x Magnetic Wand Tool for Non-Intrusive Calibration
  • Fast Global Shipping: Logistics teams dispatch orders using Fedex, UPS, or DHL express services.

Frequently Asked Questions

  • Does this unit detect toxic gases or oxygen depletion?
    • This specific configuration includes an MPD catalytic sensor designed strictly for flammable gases.
  • Can field technicians configure settings using handheld HART communicators?
    • Technicians plug HART communicators directly into the external local HART port without opening covers.
  • What thread size does this specific enclosure use for cable glands?
    • This unit features metric M25 threaded entries suitable for global industrial gland fittings.
  • How does HART EDDL software assist maintenance personnel?
    • HART EDDL software provides instant diagnostic health status readouts directly to remote control rooms.
  • What material comprises the main transmitter housing?
    • Honeywell manufactures this enclosure from painted 316 stainless steel for maximum corrosion resistance.

© 2026 Ubest Automation Limited. https://www.ubestplc.com/ All rights reserved.

Contact: Email sales@ubestplc.com Phone +86 180 3000 5825